Destination Address has to be filled.
SNMP Destination Address:
If Destination type is SNMP Trap, then enter the IP address of the system that will
receive the alert. Destination address will support the following:
· IPv4 address format.
· IPv6 address format.
BMC User Name:
If Destination type is Email Alert, then choose the user to whom the email alert has to be sent.
Email address for the user has to be configured under
Settings-->User Management
.
Email Subject & Email Message:
These fields must be configured if email alert is chosen as destination type. An
email will be sent to the configured email address of the user in case of any severity events with a subject specified in
subject field and will contain the message field’s content as the email body. These fields are not applicable for ‘AMI
-
Format’ email users.
Note:
User should be configured under
Settings
-->
User Management
Save:
To add a new entry to the device.
Delete:
To delete the selected configured LAN Destination.
Procedure
1. In the
LAN Destinations
section, choose the number of slots to be configured. This should be the same
number of slot that you have selected in the Alert Policies - Destination Selector field. That is if you have
chosen the Destination Selector as 4 in the Alert Policies page of Alert Policies tab, then you have to
configure the 4th slot of LAN Destination page.
2. Select the slot and click on the empty slot. This opens the
LAN Destination entry
.
3. In the
LAN Channel Number
field, the LAN Channel Number for the selected slot is displayed and this is a
read only field.
4. In the
LAN Destination
field, the destination for the newly configured entry is displayed and this is a read
only field.
5. In the
Destination Type
field, select the one of the types.
6. In the
SNMP Destination Address
field, enter the destination address.
Note:
If Destination type is E-mail Alert, then give the e-mail address that will receive the e-mail.
7. If the destination type is Email alert, select the
BMC User Name
from the list of users.
Note:
E-mail address should be configured under
Settings
--
>User Management
.
8. In the
Email Subject
field, enter the subject.
9. In the
Email Message
field, enter the message.
10. Click
Save
to save the new LAN destination and return to LAN destination list.
11. Click
Delete
to delete a configuration.
12. Click
Send Test Alert
to send sample alert to configured destination.
Note:
Test alert can be sent only with enabled SMTP configuration. SMTP support can be enabled under
Settings
->
SMTP Settings
.
57