Fan bay numbering
Fan mode behavior
The server supports redundant fan mode. If a fan fails, the following system behavior is exhibited:
• A single fan failure or a missing fan, the system continues to operate.
• A second fan failure or a missing fan in different fan cages, the system continues to operate.
• A second fan failure or a missing fan in the same fan cage, the operating system performs a graceful
shutdown.
Fan failure events are logged in the
Sensor Monitoring
list of the AMI MegaRAC SP-X GUI
Dashboard
page.
Drive bay numbering
1U system drive bay numbering
A single 1U server node supports two low-profile LFF SATA hot-plug drives.
2U system drive bay numbering
A single 2U server node supports two low-profile LFF SATA hot-plug drives.