Description
Item
Select the Pool Name checkbox, then enter the pool name.
Pool Name
•
Prefix: Enter the alphanumeric characters, which are fixed characters of the
head of the pool name. The characters are case-sensitive.
•
Initial Number: Enter the initial number following the prefix name, which can
be entered up to 9 digits.*
•
You can enter up to the 32 characters including the initial number. The initial
number must be 9 or less digits.
*When a pool is selected, the pool name appears in the Prefix text box by
default. When multiple pools are selected, the initial number from the set number
to the maximum number of the digit number is automatically set.
Example:
•
When 1 is set in the Initial Number field, number 1 to 9 is automatically given
to the pool name.
•
When 08 is set in the Initial Number field, number 08 to 99 is automatically
given to the pool name.
•
When 098 is set in the Initial Number field, number 098 to 999 is
automatically given to the pool name.
Select the checkbox, then enter a threshold. The minimum threshold is the pool
usage rate plus 1%. The maximum threshold is 100%.
Warning Threshold
For Fast Snap, you cannot change the setting of this function:
Check Warning Threshold and enter a threshold.
You cannot set this item if the result of the following calculation exceeds 95:
(
used-pool-capacity
/
pool-capacity
) * 100 (%)
Select the checkbox, then enter a threshold. The minimum threshold is the pool
usage rate plus 1%. The maximum threshold is 100%.
Depletion Threshold
If you change the Fast Snap pool, you cannot set this item.
Select the checkbox, then select
Yes
or
No
in the protect function for THP V-VOL.
If this function is enabled, when the pool-VOL is blocked, THP V-VOL is protected
Protect V-VOLs when I/O fails to
Blocked Pool VOL
from reading and writing requests. And at the same instant, the access attribute
of the THP V-VOL is changed to the Protect attribute.
However, if one of following is applicable, this checkbox goes inactive:
•
Data Retention is not installed.
•
Mainframe pools are selected.
Select the checkbox, then select
Yes
or
No
in the protect function for THP V-VOL.
If this function is enabled, when the pool usage reaches the full size, THP V-VOL
Protect V-VOLs when I/O fails to Full
Pool
is protected from reading and writing requests. And at the same instant, the
access attribute of the THP V-VOL is changed to the Protect attribute.
However, if one of following is applicable, this checkbox goes inactive:
•
Data Retention is not installed.
•
Mainframe pools are selected.
CAUTION:
If you want to change multiple parameters for a pool two or more times, wait until
the current task finishes, then change the next settings. If you attempt to change settings before the
current task finishes, only the settings in the next task will be applied, so the result might be different
from what you expected.
Edit Pools Confirm window
Confirm proposed settings, name the task, then click
Apply
. The task will be added to the execution
queue.
Edit Pools wizard 327
Содержание XP7