When to select this option
Host mode options
No.
When you want to change the unit attention (UA) from
NOT READY
to
MEDIUM
ERROR
during the pool-VOLs blockade.
Change the Unit Attention for
Blocked Pool-VOLs
71
When using General Parallel File System (GPFS) in the HP XP7 Storage
connecting to the AIX host.
AIX GPFS Support
72
When using following functions provided by Windows Server 2012 (WS2012)
from the environment which is being connected to the WS2012.
Support Option for WS2012
73
•
Thin Provisioning function
•
Offload Data Transfer (ODX) function
When all of following conditions are satisfied:
The non-preferred path option
78
•
High Availability is used in the configuration with the data centers (Metro
configuration).
•
Hitachi Dynamic Link Manager is used as the alternative path software.
•
The host group is on the non-optimized path of Hitachi Dynamic Link
Manager.
•
The performance deterioration of I/O responses can be avoided without
I/O using the non-optimized path of Hitachi Dynamic Link Manager.
Notes:
1.
Configure these host mode options only when requested to do so.
2.
Set the UUID when you set host mode option 33 and host mode
05 openvms
is used.
3.
Set the host mode option 51 for both ports on the local and remote storage systems.
4.
This host mode option does not support channel packages for 8FC16 and 16FE10. If these channel packages are
used, do not set the host mode option 51.
Find WWN of the host bus adapter
Before physically attaching the storage system to hosts, some preparation work needs to be
performed. When configuring a fibre channel environment, first verify that the fibre adapters and
the fibre channel device drivers are installed on the open-system hosts. Next, find the World Wide
Name (WWN) of the host bus adapter that is used in each open-system host.
The WWN is a unique identifier for a host bus adapter in an open-system host, consisting of 16
hexadecimal digits. The following topics describe how to find the WWN of a host on different
operating systems. It is best to make a record of the WWNs of the hosts in your storage system,
because you will need to enter these WWNs in LUN Manager dialog boxes to specify the hosts
used in your storage system.
•
“Finding a WWN on Windows” (page 174)
•
“Finding a WWN on Oracle® Solaris” (page 175)
•
“Finding a WWN on AIX, IRIX, or Sequent” (page 175)
•
“Finding WWN for HP-UX” (page 175)
Finding a WWN on Windows
HP supports the Emulex fibre channel adapter in a Windows environment, and will support other
adapters in the future. For further information on fibre channel adapter support, or when using a
fibre channel adapter other than Emulex, contact HP technical support for instructions on finding
the WWN.
Before attempting to acquire the WWN of the Emulex adapter, confirm whether the driver installed
in the Windows 2000 or Windows Server 2003 environment is an Emulex port driver or an Emulex
mini-port driver, then follow the driver instructions.
To find a WWN on Windows environment with an Emulex mini-port driver:
1.
Verify that the fibre channel adapters and the fibre channel device drivers are installed.
174
Managing logical volumes
Содержание XP7
Страница 229: ...Select LDEVs window Available LDEVs table Description Item LDEV identifiers LDEV ID Create Resource Groups wizard 229 ...
Страница 303: ...Pools Volume tabs Pools Volume tabs 303 ...
Страница 378: ...Add LUN Paths wizard Select LDEVs window Available LDEVs table 378 LUN Manager GUI reference ...
Страница 381: ...Select Host Groups window Available Host Groups table Add LUN Paths wizard 381 ...