External Tape Drive Installation
22
DLT VS 40/80 GB Tape Drive Reference Guide
Setting the SCSI ID
Each SCSI device attached to the server that is to be the host for the DLT VS
40/80 GB tape drive must have a unique SCSI ID. Check the SCSI IDs on all other
devices attached to the selected SCSI bus, including the SCSI host adapter itself,
on the selected server and select an unused SCSI ID for the tape drive. If the drive
factory default SCSI ID 6 is not being used by another device on the same SCSI
bus, you do not need to change the SCSI ID.
Figure 2: Rear view of tape drive
1
68-pin SCSI connectors
2
SCSI ID switch
3
Power switch
4
Power cable connector
Note:
If the tape drive is attached to a narrow SCSI bus, only IDs 0 through 7 are valid.
To set the SCSI ID use a small screwdriver or ballpoint pen to press the button
above or below the SCSI ID display.
■
Press the button above the SCSI ID display
1
to select the next lower SCSI
ID.
■
Press the button below the SCSI ID display
2
to select the next higher SCSI
ID.
1
2
3
4
Содержание StorageWorks DLT VS 40
Страница 6: ...Contents 6 DLT VS 40 80 GB Tape Drive Reference Guide ...
Страница 14: ...About this Guide 14 DLT VS 40 80 GB Tape Drive Reference Guide ...
Страница 18: ...Introduction 18 DLT VS 40 80 GB Tape Drive Reference Guide ...
Страница 48: ...Operating the DLT VS 40 80 Tape Drive 48 DLT VS 40 80 GB Tape Drive Reference Guide ...
Страница 60: ...Regulatory Compliance Notices 60 DLT VS 40 80 GB Tape Drive Reference Guide ...
Страница 66: ...Specifications 66 DLT VS 40 80 GB Tape Drive Reference Guide ...