58 Product Overview
possibility of data loss in the event of multiple disk failures. Although the
statistical advantage of this minimal but measurable, HP advises when ever
possible to keep an even number of disks in each redundancy group.
For optimum availability, it is recommended that you have an even number of
disks in each redundancy group. Because of the manner in which the array
stores data, an even number of disks reduces the possibility of data loss in the
event of multiple disk failures. Although the possibility of this is extremely low,
using an even number of disk reduces the risk even further.
Auto Rebuild Behavior
(Firmware version HP14 and greater)
When a disk fails and Auto Rebuild is enabled, the array always attempts to
rebuild the data on the failed disk. This will occur even if the array may not
have enough capacity to complete the rebuild. For example, if hot sparing has
been disabled, there may not be enough capacity available to complete a
rebuild.
The array first makes an attempt to rebuild any data that was stored in
RAID1+0. This data is more vulnerable to another disk failure than data stored
in RAID 5DP. The array will continue to perform the rebuild until there is no
longer any capacity available to continue. This situation may result in
diminished performance when new data is written to the array in this
condition. The performance impact increases with the number of disks in the
redundancy group.
To avoid this situation, it is recommended that in configurations with 15 or
more disks per redundancy group, that Auto Rebuild is disabled whenever hot
spare is disabled.
Содержание StorageWorks 7110 - Virtual Array
Страница 12: ...12 Contents ...
Страница 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Страница 90: ...90 Troubleshooting ...
Страница 113: ...Servicing Upgrading 113 Servicing Upgrading Figure 43 Removing Installing a VA 7100 Controller 1 2 3 4 ...
Страница 114: ...114 Servicing Upgrading Figure 44 Removing Installing a VA 7110 7400 7410 Array Controller 1 2 3 ...
Страница 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Страница 119: ...Servicing Upgrading 119 Servicing Upgrading Figure 47 Connecting an Array Controller Battery 1 3 4 5 2 ...
Страница 124: ...124 Servicing Upgrading Figure 49 Removing Installing a Midplane Assembly 2 1 4 5 8 7 9 10 6 3 ...
Страница 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Страница 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Страница 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Страница 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Страница 152: ...152 Specifications Regulatory Statements ...
Страница 164: ...164 Index ...