Installing and Configuring the Director
50
Director 2/140 Installation Guide
Securing the Rear Mounting Brackets to the Rack
Follow this procedure to attach the Director 2/140 rear mounting plates to the rack
using the rear mounting bracket:
1. Align a rear mounting bracket with the cage nuts you installed earlier, and the
screw holes in the rear mounting plate attached to the Director 2/140.
2. Attach a rear mounting bracket to a rear mounting plate by installing three (3)
Phillips panhead screws in the mounting plate holes. Do not tighten.
3. Adjust the position of the rear bracket so that the holes align with the cage
nuts installed in the cabinet rail.
4. Attach the rear mounting bracket to the cage nuts installed in the cabinet rail
using three (3) Phillips panhead screws. Tighten securely.
5. Tighten the screws attached to the rear mounting plate.
6. Repeat
step 1
through
step 5
to attach a rear mounting bracket to the
remaining rear rail.
Connecting the Director to a Power Source
The Director 2/140 includes two power supplies (labeled PS0 and PS1 on the rear
of the unit) for redundancy. Each power supply must be connected to an
appropriate power source that provides 220-volt AC power.
The Director 2/140 is shipped with the following power cords:
■
Two (2) PDU (power distribution unit) power cords
■
Two (2) 110-volt AC power cords (for Director 2/64 only)
Note:
The 110-volt AC power cords provided in the kit are not for use with the Director
2/140. For more information, see the
HP StorageWorks Director Power Cord Advisory.
WARNING:
To prevent electric shock, use only the supplied PDU power
cord(s). Also, verify that the facility power receptacle is the correct type,
supplies the required voltage, and is properly grounded.
Connect each Director 2/140 power supply to a Power Distribution Unit (PDU)
receptacle using a PDU power cord as shown in