Installing and Configuring the Director
40
Director 2/140 Installation Guide
Unpack, Inspect, and Install the Director
The following paragraphs provide instructions to unpack and inspect one or more
Director 2/140s, and install the directors on a desktop or in a rack-mount
configuration.
Unpack and Inspect the Director
Unpack and inspect the director(s) as follows:
1. Inspect the shipping containers for damage caused during transit. If a
container is damaged, ensure a representative from the freight carrier is
present when the container is opened.
2. Unpack the shipping containers and inspect each item for damage. Ensure the
items match the items listed on the bill of materials (BOM).
3. If any items are damaged or missing, customers should call the toll-free
telephone number printed on the service label attached to the back of the
director.
Install the Director on a Desktop
To install the director on a desktop:
1. Position the director on a table or desktop as directed by the customer.
Caution:
Four person lift
—
the director weighs approximately 167 lbs. Do not
attempt to lift or carry the director with fewer than four people. Failure to
observe this CAUTION may result in injury to personnel or damage to the
director.
2. Verify all field-replaceable units (FRUs), including logic cards, fans, and
power supplies are installed as ordered.
3. Connect the U.S. or country-specific (optional) AC power cords to the right
(PS0) and left (PS1) receptacles at the rear of the director, as shown in