Chapter 6: Power supply maintenance
33
Install a power supply
Before you begin
You have completed these tasks:
• Obtained a replacement power supply of the same type and wattage.
• Removed the failed power supply from the server.
• Read the guidelines for maintaining power supplies.
• Read the guidelines for protecting components from electrostatic discharge.
Procedure overview
You install a power supply, or filler panel, to replace a failed or failing power supply.
Procedure
1.
Carefully remove the replacement power supply from its packaging.
2.
Slide the power supply into the empty bay until the red latch engages.
3.
Ensure that the power supply is fully inserted and locked in place by the red, spring-loaded clip.
4.
Connect and secure the power cable to the new power supply and to the power source.
5.
Ensure that the power cables are fully inserted at both ends.
6.
Power up the server.
7.
Examine the LEDs and event messages to ensure the power supply is operational.