
Chapter 4: Server troubleshooting
26
Server state LED 1
LED 2
Description
Off
Flashing red (1 on,
1 off)
Field Programmable Gate Array (FPGA)
configuration error detected or configuration
failed.
Off
Solid green
FPGA configuration is complete.
Off
Flashing red
(2 on, 2 off)
Firmware is not responding to health check.
Flashing yellow
Solid green
Power-on self test (POST) is executing.
Solid yellow
Solid red
POST failed.
POST
Solid green
Solid green
Normal operation (passed POST).
State save
Solid yellow
Flashing green
NVRAM state save is in progress.
State restore
Flashing yellow
Flashing green
NVRAM state restore is in progress.
Upgrade
Flashing green
Flashing green
Firmware upgrade is in progress.
HostCtrl
Flashing yellow
Flashing red
Not in service. Contact
Customer Support
(http://www.hpe.com/support/hpesc)
for a
replacement.
Accelerator card not detected
If the server is unable to detect or communicate with an Accelerator card after you power on the server or perform
a server firmware upgrade, you see error conditions.
LED number Initial state
Error state (Host Ctrl)
After power up
After software upgrade
1
Off
Solid green
Off
2
Off
Solid yellow
Flashing yellow
A firmware load error on the Accelerator card might have caused the problem. You can try to correct this problem: