QuickSpecs
HPE ProLiant XL250a Gen9 Server
Technical Specifications
Page 31
System Unit
Server Dimensions
(L x W x D)
8.33 x 3.49 x 27.87 in (21.15 x 8.76 x 70.79 cm)
Shipping Dimensions
(L x W x D)
37.76 x 14.88 x 10.63 in (95.91 x 37.80 x 27.00 cm)
Weight
(approximate)
Maximum
(maximum: two
processors, six hard
drives, two Accelerators)
30 lb. (13.61 kg)
System Inlet
Temperature
Standard Operating
Support
Extended Ambient
Operating Support
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
20°C/hr (36°F/hr). The upper limit and rate of
change may be limited by the type and number
of options installed.
System performance during standard operating
support may be reduced if operating with a fan
fault or above 30°C (86°F).
For approved hardware configurations, the
supported system inlet range is extended to be:
5° to 10°C (41° to 50°F) and 35° to 40°C (95° to
104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft)
above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft). The approved hardware
configurations for this system are listed at the
URL:
http://www.hpe.com/servers/ASHRAE
For approved hardware configurations, the
supported system inlet range is extended to be:
40° to 45°C (104° to 113°F) at sea level with an
altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are
listed at the URL:
http://www.hpe.com/servers/ASHRAE
System performance may be reduced if
operating in the extended ambient operating
range or with a fan fault.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).