Relative Humidity
(non-condensing)
Operating
Minimum to be the higher (more moisture) of -
12°C (10.4°F) dew point or 8% relative humidity.
Maximum to be the lower (less moisture) of
24°C (75.2°F) dew point or 90% relative
humidity.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
measured average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109). The listed sound
levels apply to standard shipping configurations. Additional options may
result in increased sound levels.
Configuration
SKU
Entry
Base
Performance
Idle
LWAd
6.9 B
6.9 B
6.9 B
LpAm
51 dBA
51 dBA
51 dBA
Operating
LWAd
8.0 B
8.3 B
8.7 B
LpAm
62 dBA
66 dBA
72 dBA
NOTE:
Entry- CPU*2(E5-2683v3, 120W, 14c), DDR4 DIMM*4(8GB 1Rx4),
HDD*1(900GB 6G SAS 10K 2.5in ENT) 2
NOTE:
Base- CPU*2(E5-2683v3, 120W, 14c), DDR4 DIMM*8(8GB 1Rx4),
HDD*2(900GB 6G SAS 10K 2.5in ENT) 3
NOTE:
Performance- CPU*2(E5-2690v3, 135W, 12c), DDR4
DIMM*16(16GB 2Rx4), HDD*4(900GB 6G SAS 10K 2.5in ENT)
NOTE:
Values are subject to change without notification and are for
reference only.
NOTE:
Performance of system, options, and ancillary equipment will
vary depending on the system configuration.
NOTE:
Levels presented do not account for non-Hewlett Packard
Enterprise installed hardware.
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt
15; ICES-003; CNS13438; GB9254; K22;K24; EN
61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1