Battery replacement 76
Battery replacement
If the workstation blade no longer automatically displays the correct date and time, you may need to
replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10
years.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
Power down the workstation blade (on page
12
).
2.
Remove the workstation blade (on page
13
).
3.
Remove the access panel (on page
14
).
4.
Identify the battery location ("
System board components
" on page
9
).
5.
Remove the battery tray.