Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
10,000 ft (3048 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable altitude
change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
L
WAd
7.1 Bels
L
pAm
54 dB
Operating
L
WAd
7.3 Bels
L
pAm
57 dB
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;
ICES-003; CNS13438; K22;K24; EN 61000-3-2; EN
61000-3-3; EN 60950-1; IEC 60950-1
NOTE:
Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
Broadcom 5720 Adapter
Network Interface
Compatibility
IEEE 1588, IEEE 802.1AS
IEEE 802.3az
Data Transfer Method
PCI Express v 2.1, 5.0 GT/s and 2.5 GT/s bus speeds and supports for x1, x2, x4
links widths (Lanes)
Controller
Network Transfer Rate
10Mb(Half-Duplex)
10 Mb/s per port, 20 Mb/s Combined
10Mb (Full-Duplex)
20 Mb/s per port, 40 Mb/S Combined
100Mb (Half-Duplex)
100 Mb/s per port, 200 Mb/s Combined
100Mb(Full-Duplex)
200 Mb/s per port, 400 Mb/s Combined
1Gb(Half and Full-Duplex)
1000Mb/s per port, 2000 Mb/s
Combined
Connector
Internal
Cable Support
N/A
QuickSpecs
HP ProLiant Moonshot Server
Technical Specifications
DA - 14527 Worldwide — Version 6 — December 9, 2013