background image

As a dedicated hosting company are you using large numbers of traditionally architected servers? Are you hitting the wall for power,
cooling and space?
The HP Moonshot System uses an innovative new architecture that results from one simple design tenet: to align purpose-built modules
with the right workload to provide optimal results for your dedicated hosting environment. Traditional servers rely on dedicated
components, including management, networking, storage, power cords and cooling fans in a single chassis. In contrast, the Moonshot
system share these chassis components and are capable of supporting 45 servers per 4.3U chassis.
This gives you the ability to generate greater revenue from a smaller footprint while driving down your operational costs. The HP
ProLiant Moonshot Servers use low-energy processors and direct attached disk drives to provide an ideal solution for dedicated hosting.

Front View:

Back View:

1.

Chassis Power LED

1.

Fans

12. SD card slot

2.

System health LED

2.

Fan LED

13. HP Moonshot 1500 Chassis

Management Module

3.

Chassis UID/LED/button

3.

HP Moonshot-6SFP Uplink
Module B

14. Switch module

uplink/downlink activity LEDs

4.

Front Panel Display LED, Moonshot server 1-18

4.

Chassis management
module release lever

15. Power supply connector

5.

Switch Module A Health LED

5.

HP Moonshot 1500 Chassis
Management Module UID
LED/button

16. 10Gb SFP connector (x6)

6.

Front Panel Display LED, Moonshot server 19-27

6.

Serial port

17. Serial connector

7.

Switch module B health LED

7.

Rack control modular
connection

18. Uplink module UID/LED

button

8.

Front Panel Display LED, Moonshot server 28-45

8.

USB port

19. Uplink module health LED

9.

Front Panel Display release

9.

HP Moonshot 1500 Chassis
Management module LED

20. HP Moonshot-6SFP Uplink

Module A

 

 

10. iLO2 connector

21. Uplink module release lever

 

 

11. iLO1 connector (primary)

 

 

QuickSpecs

HP ProLiant Moonshot Server

Overview

DA - 14527   Worldwide — Version 6 — December 9, 2013

Page  1

Содержание ProLiant Moonshot

Страница 1: ...l solution for dedicated hosting Front View Back View 1 Chassis Power LED 1 Fans 12 SD card slot 2 System health LED 2 Fan LED 13 HP Moonshot 1500 Chassis Management Module 3 Chassis UID LED button 3 HP Moonshot 6SFP Uplink Module B 14 Switch module uplink downlink activity LEDs 4 Front Panel Display LED Moonshot server 1 18 4 Chassis management module release lever 15 Power supply connector 5 Swi...

Страница 2: ...ered UDIMM ECC 1333 MHz DIMM Slots Available 1 SO DIMM Slot Configuration 8GB 1x8GB Network Controller Network Controller Broadcom 5720 Dual port 1Gb Ethernet Controller Storage Controller Marvell 9125 Storage Device Hard Drive Each cartridge will ship with a SATA HDD or SATA SSD Maximum Internal Storage per Moonshot Server Quick Release SATA 2 5 1TB 1 x 1TB SATA 500 GB 1 x 500 GB SATA QuickSpecs ...

Страница 3: ...ions of these operating systems are supported NOTE For more information on HP s Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server including how to purchase from HP please visit our OS Support Site at http www hp com go ossupport and our driver download page http www hp com go servers Moonshot download Server...

Страница 4: ... chassis and server settings and control server power and UID lights use Virtual Serial Port to servers and to flash firmware in the chassis It also supports IPMI management On System Management HP Moonshot iLO Chassis Management Firmware is the gateway for aggregated chassis management on HP Moonshot Moonshot iLO CM firmware reduces cost and power by sharing four iLO modules across the nodes and ...

Страница 5: ...f up to 94 and are available in only a 1200W configuration for this platform which is right sized for this specific solution All HP Common Slot power sources are UL CE Mark Compliant hot plug and support redundant configurations HP Power Advisor can be accessed at www hp com go hppoweradvisor NOTE Mixing of power supplies in the same server is not supported All power supplies must be of the same o...

Страница 6: ...es CMU makes the administration of clusters user friendly efficient and effective http www hp com go cmu Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and storage products Customers can choose how their factory solutions are built tested integrated shipped and deployed Factory Express offer...

Страница 7: ...d software For a complete list of software products covered refer to www hp com services collaborativesupport Full software support including call management and ownership thru to resolution is available for select third party software As stated earlier support for Ubuntu software is included in the purchase of your Moonshot chassis HP Datacenter Care HP Datacenter Care offers you a flexible tailo...

Страница 8: ...yson HP Care Pack services www hp com services carepack Recommended HP Care Pack Services for your HP product Optimized Care 3 Year HP Foundation Care Call to Repair This is HP s highest level of reactive support giving you our commitment to have the hardware operational within six hours of opening the call with us This service level includes hardware coverage plus software diagnosis support with ...

Страница 9: ...s to information tools and experts to support HP business products Submit support cases online chat with HP experts access support resources or collaborate with peers Learn more http www hp com go hpsc HP s Support Center Mobile App allows you to resolve issues yourself or quickly connect to an agent for live support Now you can get access to personalize IT support anywhere anytime HP Support Cent...

Страница 10: ...rder a total of 45 identically configured Moonshot servers to complete the chassis 700350 B21 Step 1A Configure Moonshot Servers one of each unless otherwise noted HP Moonshot Server HP ProLiant Moonshot Server NOTE Must order a total of 45 identically configured Moonshot servers to complete the chassis NOTE Each Moonshot server comes preconfigured with a single 8 GB SO DIMM pre installed This is ...

Страница 11: ...itch Kit and Uplink Kit per chassis to allow configurations with redundant or dual networks Step 3 Choose additional options HP Insight Software HP Insight Control including 1yr 24x7 Support ProLiant ML DL BL bundle Single Server FIO License C6N36A HP Power Cords HP C13 Nema 5 15P US CA 110V 10Amp 1 83m Power Cord AF556A HP C13 GB 1002 CN 250V 10Amp 1 83m Power Cord AF557A HP C13 IRAM 2073 AR 250V...

Страница 12: ...V 10Amp 2 0m Jumper Cord A0K02A HP C13 C14 WW 250V 10A Gray 0 7m Jumper Cord A0K03A HP C13 C14 WW 250V 10A Gray 1 37m Jumper Cord A0K04A HP C13 C14 WW 250V 10A Gray 3 0m Jumper Cord A0K06A HP C13 Nema 6 15P US 250V 15A JP 3 6m Power Cord A0N33A QuickSpecs HP ProLiant Moonshot Server Configuration Information Factory Integrated Models DA 14527 Worldwide Version 6 December 9 2013 Page 12 ...

Страница 13: ...e license activation key s Includes one year of 24 x 7 HP Software Technical Support and Update Service NOTE Licenses ship without media The HP Insight Control Media Kit can be ordered separately or can be downloaded at http www hp com go insightupdates NOTE For additional license options please see the QuickSpecs at http h18000 www1 hp com products quickspecs 12631_div 12631_div html High Perform...

Страница 14: ...ank Kit 681260 B21 NOTE For data center airflow management purposes it is recommended that either the 66U Spacer Blank or the 13U FIO Rack Adapter Kit can be ordered NOTE The HP 4 3U Rail Kit is required to be ordered for every chassis to properly install the chassis into a rack NOTE The 66U Spacer Blank kit may be ordered and will give an even 5U 4 3U 0 66U spacing in a rack This would enable ins...

Страница 15: ...P Uninterruptible Power System AF462A HP R7KVA 4U IEC 32A High Voltage INTL Uninterruptible Power System AF463A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14110_div 14110_div html Worldwide NOTE For additional information on HP Uninterruptible Power Systems please go to www hp com servers rackups NOTE For additional information on sizing y...

Страница 16: ...ts HP 4 9kVA 24A Single Phase NA JP Core Intelligent Modular Power Distribution Unit AF520A HP 8 6kVA 24A Three Phase NA JP Core Intelligent Modular Power Distribution Unit AF522A HP 7 3kVA 32A Single Phase INTL Core Intelligent Modular Power Distribution Unit AF525A HP 11kVA 16A Three Phase INTL Core Intelligent Modular Power Distribution Unit AF526A iPDU Extension Bars HP 5xC13 Intelligent PDU E...

Страница 17: ..._div html Worldwide NOTE Additional HP Power Distribution Units are available For a complete list of all HP PDUs and additional information please visit www hp com go rackandpower HP Rack Series HP Intelligent Series Rack HP 636 1200mm Pallet Intelligent Series Rack BW899A HP 636 1200mm Shock Intelligent Series Rack BW900A HP 642 1200mm Pallet Intelligent Series Rack BW907A HP 642 1200mm Shock Int...

Страница 18: ... Analog Switch AF616A HP Server Console 0x2x16 Port Analog Switch AF617A HP TAA 0x2x16xKVM Server Console G2 Switch AF626A NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 11834_div 11834_div html Worldwide HP Server Console Switch G2 with Virtual Media CAC HP 0x2x16 KVM Server Console Switch G2 with Virtual Media CA...

Страница 19: ...at 230VAC Rated Input Frequency 47 to 63 Hz Rated Input Power 855W at 100 VAC 840 72W at 200 VAC Power Specifications To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL www hp com go proliant energy efficient Power Supply Output per power supply Rated Steady State Power 653 10W at 100 VAC 653 08W at 200 VAC System Inlet Temperature...

Страница 20: ...mative Standards CISPR 22 EN55022 EN55024 FCC CFR 47 Pt 15 ICES 003 CNS13438 K22 K24 EN 61000 3 2 EN 61000 3 3 EN 60950 1 IEC 60950 1 NOTE Product conformance to cited product specifications is based on sample type testing evaluation or assessment This product or family of products is eligible to bear the appropriate compliance logos and statements Broadcom 5720 Adapter Network Interface Compatibi...

Страница 21: ...by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2013 Hewlett Packard Development Company L P The information contained herein is subject to change ...

Отзывы: