![HP ProLiant ML350p Gen8 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/hp/proliant-ml350p-gen8/proliant-ml350p-gen8_maintenance-and-service-manual_164880050.webp)
Removal and replacement procedures 50
SFF drive backplane
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
27
).
o
For rack models, if installed, remove the security bezel (on page
27
).
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
For tower models, do the following:
a.
Place the server on a flat, level surface with the access panel facing up.
b.
Remove the access panel ("
Access panel
" on page
29
).
5.
For rack models, do the following:
a.
Extend the server from the rack (on page
28
).
b.
Remove the access panel ("
Access panel
" on page
29
).
c.
Release thumbscrews and remove the rack bezel.
6.
Disconnect all cables from the drive backplane.
7.
Using a T-15 screwdriver, remove the screws that secure the SFF drive cage to the server.
Содержание ProLiant ML350p Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 23: ...Illustrated parts catalog 23 ...