Removal and replacement procedures 39
b.
Disconnect each power cord from the server.
4.
For tower models, do the following:
a.
Place the server on a flat, level surface with the access panel facing up.
b.
Remove the access panel ("
Access panel
" on page
29
).
5.
For rack models, do the following:
a.
Extend the server from the rack (on page
28
).
b.
Remove the access panel ("
Access panel
" on page
29
).
c.
Release thumbscrews and remove the rack bezel.
6.
Remove the air baffle ("
Air baffle
" on page
30
).
7.
Remove the fan cage.
8.
Disconnect and remove the optical drive power and data cables.
9.
Remove the optical drive.
To replace the component, reverse the removal procedure.
Front I/O assembly
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
27
).
o
For rack models, if installed, remove the security bezel (on page
27
).
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
For tower models, do the following:
a.
Place the server on a flat, level surface with the access panel facing up.