Removal and replacement procedures 48
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
28
).
5.
Remove the access panel ("
Access panel
" on page
29
).
6.
Remove the air baffle ("
Air baffle
" on page
30
).
7.
Disconnect the capacitor pack cable from the cache module.
8.
Remove the cache module.
To replace the component, reverse the removal procedure.