Specifications 85
HP 350 W 4U Integrated Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
47 Hz to 63 Hz
Rated input current
6 A
Rated input power
440 W at 100 V AC input
440 W at 200 V AC input
Efficiency
No less than 82% at 100% load
No less than 85% at 50% load
No less than 82% at 20% load
Power supply output
—
Rated steady-state power
350 W at 100 V AC input
350 W at 200 V AC input
Maximum peak power
400 W at 100 V AC input
400 W at 200 V AC input
Rated output power
350 W
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6 A to 3 A
Rated input power
526 W at 115 V AC input
523 W at 230 V AC input
Power supply output
—
Efficiency
Not less than 87.5% at 100% load
Not less than 89.5% at 50% load
Not less than 87.5% at 20% load
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the HP Power Advisor website (
http://www.hp.com/go/hppoweradvisor
).
Содержание ProLiant ML310e Gen
Страница 5: ...Contents 5 Acronyms and abbreviations 87 Documentation feedback 90 Index 91 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 18: ...Illustrated parts catalog 18 ...
Страница 73: ...Component identification 73 Drive numbering Four bay LFF drive model Eight bay SFF drive model ...