Removal and replacement procedures 51
7.
Remove the iLO module from the chassis.
To replace the component, reverse the removal procedure.
Enabling the dedicated iLO management port
The onboard NIC 1/shared iLO connector is set as the default system iLO port.
To enable the installed dedicated iLO module:
1.
During the server startup sequence after module installation, to access iLO RBSU, press the
F8
key.
2.
Select the
Network
menu.
3.
Click the
Network Interface Adapter
field.
4.
To change the setting to
ON
, press the spacebar.
5.
To save the new settings, press the
F10
key.
6.
Select the
File
menu, and then to close iLO RBSU, click
Exit
.
7.
To confirm exiting iLO RBSU, click
OK
. The server automatically reboots.
IMPORTANT:
If the iLO RBSU settings are reset to the default values, access to the machine will be
lost. Access the physical machine, and then set the
Network Interface Adapter
field to
ON
.
Non-hot-plug power supply
To remove the component:
1.
Power down the server (on page
26
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Unlock the tower bezel.
4.
Remove the access panel ("
Access panel
" on page
31
).
Содержание ProLiant ML310e Gen
Страница 5: ...Contents 5 Acronyms and abbreviations 87 Documentation feedback 90 Index 91 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 18: ...Illustrated parts catalog 18 ...
Страница 73: ...Component identification 73 Drive numbering Four bay LFF drive model Eight bay SFF drive model ...