Error messages 97
Controller Reported POST Error. Error Code: X
Description
: The controller returned an error from its internal POST.
Action
: Replace the controller.
Controller Restarted with a Signature of Zero
Description
: ADU ("
Array diagnostic software
" on page
77
) did not find a valid configuration signature to
use to get the data. NVRAM may not be present (unconfigured) or the signature present in NVRAM may not
match the signature on the controller.
Action
: Run the server setup utility to configure the controller and NVRAM.
Disable Command Issued
Description
: The issuing of the Accelerator Disable command has disabled posted-writes. This occurred
because of an operating system device driver.
Action
: Restart the system. Run ACU ("
Array Configuration Utility
" on page
71
) to reinitialize the array
accelerator board.
Drive (Bay) X Firmware Needs Upgrading
Description
: Firmware on this physical drive is below the latest recommended version.
Action
: Update the drive to the latest firmware version ("
Firmware maintenance
" on page
81
).
Drive (Bay) X has Insufficient Capacity for its Configuration
Description
: Drive has insufficient capacity to be used in this logical drive configuration.
Action
: Replace this drive with a larger capacity drive.
Drive (Bay) X has Invalid M&P Stamp
Description
: Physical drive has invalid monitor and performance data.
Action
: Run the server setup utility to properly initialize this drive.
Drive (Bay) X Has Loose Cable
Description
: The array controller could not communicate with this drive at power-up. This drive has not
previously failed.
Action
:
1.
Be sure all cables are properly connected and working.
2.
Power down the system and attempt to reconnect data/power cable to the drive.
3.
Power up the system.
4.
If the problem persists, power down the system and replace the cable.
5.
If the problem persists, power down the system and replace the drive.