Error messages 154
1783-Slot X Drive Array Controller Failure
Audible Beeps
: None
Possible Cause
: The controller failed.
Action
:
1.
Reseat the array accelerator module.
2.
Reseat the controller in the PCI slot.
3.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
81
).
4.
If the problem persists, replace the controller.
1784-Slot X Drive Array Drive Failure. The Following SCSI Drive(s) Should Be
Replaced: SCSI Port Y: SCSI ID Z
Audible Beeps
: None
Possible Cause
: Defective drive or SCSI cables detected.
Action
:
1.
Be sure all cables are connected properly and securely.
2.
Be sure all drives are fully seated.
3.
Replace defective cables, drive
X
, or both.
1785-Slot X Drive Array Not Configured...
(followed by one of the following):
...(1) Run Array Configuration Utility
(2) No drives detected
(3) Drive positions appear to have changed – Run Drive Array Advanced Diagnostics if previous positions are
unknown. Then turn system power OFF and move drives to their original positions.
(4) Configuration information indicates drive positions beyond the capability of this controller. This may be due to drive
movement from a controller that supports more drives than the current controller.
(5) Configuration information indicates drives were configured on a controller with a newer firmware version.
Audible Beeps
: None
Possible Cause
: Drive array configuration not detected.
Action
:
•
Run ACU ("
Array Configuration Utility
" on page
71
).
•
Power down the system and check SCSI cable connections to be sure the drives are connected properly.
•
Run ADU ("
Array diagnostic software
" on page
77
) if previous positions are unknown. Then, turn the
system power off and move the drives to their original positions.
•
To avoid data loss, update the controller firmware to the same or later version on the original controller
("
Firmware maintenance
" on page
81
).