Error messages 151
Action
:
•
Press the
F2
key to accept the data loss and re-enable the logical drives.
•
Restore data from backup.
•
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps
: None
Possible Cause
: Drive firmware update needed.
Action
: The indicated drives are running firmware that is known to cause intermittent problems. Update all
drives to the latest firmware version ("
Firmware maintenance
" on page
81
).
1774-Slot X Drive Array - Obsolete Data Found in Array Accelerator
Audible Beeps
: None
Possible Cause
: Drives were used on another controller and reconnected to the original controller while data
was in the original controller cache. Data found in the array accelerator is older than data found on the
drives and has been automatically discarded.
Action
: Check the file system to determine whether any data has been lost.
1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:
...Check storage system power switch and cables. Turn the system power off while checking the ProLiant power and
cable connections, then turn the system power back on to retry.
Audible Beeps
: None
Possible Cause
: Storage system problem detected. A SCSI enclosure seems to be connected to the specified
SCSI bus, but no drives or SCSI backplane processor were detected on this bus.
Action
:
1.
Power down the server.
2.
Check the external ProLiant power switch. External drives must all be powered up before the main
system is.
3.
Be sure the cables are connected properly and securely.
4.
Update the storage device to the latest firmware version ("
Firmware maintenance
" on page
81
).
5.
If the problem persists, replace the cable, backplane, or Smart Array Controller.
1775-Slot X Drive Array - Storage Enclosure Cabling Problem Detected - OUT port of
this box is attached to OUT port of previous box.
...Turn system and storage box power OFF and check cables. Drives in this box and connections beyond it will not be
available until the cables are attached correctly.
Audible Beeps
: None
Action
: For cabling configuration information, see the storage enclosure documentation.