Error messages 144
Audible Beeps
: None
Possible Cause
: Drive parameter tracking reports a predictive-failure condition on the indicated drive. It may
fail at some time in the future.
Action
:
•
If the drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and
restore all data afterward.
•
If the drive is part of a fault-tolerant configuration, do not replace the drive unless all other drives in the
array are online.
1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ...
...Logical drive configuration has automatically been updated.
Audible Beeps
: None
Possible Cause
: The logical drive configuration has been updated automatically following physical drive
position changes.
Action
: No action is required.
1725-Slot X Drive Array-Optional SIMM Failure Detected
Audible Beeps
: None
Possible Cause
: SIMM has been automatically disabled due to memory errors or unsupported SIMM type
installed.
Action
: Replace the SIMM memory module on the indicated controller.
1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ...
...Array Accelerator configuration has automatically been updated.
Audible Beeps
: None
Possible Cause
: The array accelerator configuration has been updated automatically due to replacement of
the array accelerator (or controller) with one having different cache memory size.
Action
: Run the ACU ("
Array Configuration Utility
" on page
71
) to change the default cache read/write
allocation ratio.
1726-Slot X Drive Array - Cache Memory Size or Battery Presence Has Changed
...Array Accelerator configuration has automatically been updated.
Audible Beeps
: None
Possible Cause
: The array accelerator configuration has been updated automatically due to replacement of
the array accelerator (or controller) with one having different cache memory size. This message may also
appear following removal or installation of the cache battery back.
Action
: To change the default cache read/write allocation ratio, run the ACU ("
Array Configuration Utility
"
on page
71
).
1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected...
...If more than 32 logical drives, this message will be followed by: “Auto-configuration failed: Too many logical drives.”