NOTE:
When updating the individual components, the Smart Components will detect if the
component is already at the correct revision by displaying the message pictured below. For
components other than is CPLD, you can select "Close" and continue with the rest of the
firmware update process. For the CPLD, you must select "install" and update the CPLD.
TIP:
The estimated time for this update is approximately one hour.
a.
Download the Smart Component to a directory on the hard drive and change to that
directory.
•
Download the CPLD firmware for the Windows operating system (
pub/softlib2/software1/sc-windows-fw/p350928355/v68911
).
•
Download the CPLD firmware for the Linux operating system (
softlib2/software1/sc-linux-fw/p290132142/v68931
).
b.
From that drive and directory, execute the downloaded file. Linux users can execute "sh
CPxxxxxx.scexe" where CPxxxxxx.scexe represents the filename of the component. Click
"Install" when prompted.
c.
If the first update pass fails, retry flashing the CPLD.
d.
If the second update pass fails, browse to the iLO web information Diagnostics tab and
use the Reset button to reset iLO.
e.
Retry flashing the CPLD.
f.
Upon successful update, the following dialog box will appear.
Do not restart the server
at this time.
CAUTION:
Do not power off or power down the server until the firmware for all
components in this procedure have been updated.
11.
Flash the FMP using the FMP Smart Component.
NOTE:
When updating the individual components, the Smart Components will detect if the
component is already at the correct revision by displaying the message pictured below. For
components other than is CPLD, you can select "Close" and continue with the rest of the
firmware update process. For the CPLD, you must select "install" and update the CPLD.
80
Flashing firmware
Содержание ProLiant DL980 G7
Страница 8: ...8 Illustrated parts catalog ...
Страница 92: ...Fan location 92 Component identification ...
Страница 93: ...Description Item Fan 4 1 Fan 3 2 Fan 2 3 Fan 1 4 Fan module 6 5 Fan module 5 6 Fan location 93 ...
Страница 112: ...V video connector 96 VMware ESX Server configuring 82 X XNC Module 67 1 12 Index ...