6.
Remove all components from the failed SPI board.
To replace the component, reverse the removal procedure.
Systems Insight Display assembly
CAUTION:
When routing cables, always be sure that the cables are not in a position where
they can be pinched or crimped.
To remove the component:
1.
Power off the server (
“Power off the server” (page 22)
).
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Using a T-10 Torx screwdriver, release the two locking latches on the top of the SID bezel.
5.
Pull the bezel up and away from the server.
6.
Disconnect the cable from the rear of the Systems Insight Display assembly.
7.
Remove the retaining screw.
8.
Remove the Systems Insight Display assembly.
Systems Insight Display assembly
57