4.
Slide the server back into the rack.
5.
Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during the
manufacturing process and should NOT be modified. This option should only be used by
qualified service personnel. This value should always match the serial number sticker located
on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel. This value
should always match the serial number located on the chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.
7.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified personnel. This value should
always match the Product ID on the chassis.
8.
Enter the product ID and press the
Enter
key.
9.
Press the
Esc
key to close the menu.
10.
Press the
Esc
key to exit RBSU.
11.
Press the
F10
key to confirm exiting RBSU. The server automatically reboots.
Re-entering the server serial number and product ID
After you replace the SPI board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Serial Number.
The following warning is displayed:
Warning: The serial number should ONLY be modified by qualified service personnel. This
value should always match the serial number located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number.
6.
Select
Product ID.
The following warning is displayed:
Warning: The Product ID should ONLY be modified by qualified service personnel. This value
should always match the Product ID located on the chassis.
7.
Enter the product ID, and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
10.
Press the
F10
key to confirm exiting RBSU. The server automatically reboots.
Power backplane
To remove the component:
1.
Power off the server (
“Power off the server” (page 22)
).
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Remove all power supplies (
“Hot-plug power supply” (page 24)
).
5.
Remove the XNC module (
).
70
Removal and replacement procedures
Содержание ProLiant DL980 G7
Страница 8: ...8 Illustrated parts catalog ...
Страница 92: ...Fan location 92 Component identification ...
Страница 93: ...Description Item Fan 4 1 Fan 3 2 Fan 2 3 Fan 1 4 Fan module 6 5 Fan module 5 6 Fan location 93 ...
Страница 112: ...V video connector 96 VMware ESX Server configuring 82 X XNC Module 67 1 12 Index ...