Hardware options installation 53
contents of the degraded rank to the online spare rank. The server then deactivates the failing rank and
automatically switches over to the online spare rank.
Lockstep memory configuration
Lockstep mode provides protection against multi-bit memory errors that occur on the same DRAM device.
Lockstep mode can correct any single DRAM device failure on x4 and x8 DIMM types. The DIMMs in each
channel must have identical HP part numbers.
General DIMM slot population guidelines
Observe the following guidelines for all AMP modes:
•
Install DIMMs only if the corresponding processor is installed.
•
When two processors are installed, balance the DIMMs across the two processors.
•
White DIMM slots denote the first slot of a channel (Ch 1-A, Ch 2-B, Ch 3-C, Ch 4-D).
•
Do not mix LRDIMMs, UDIMMs, RDIMMs, or HDIMMs.
•
Do not install more than two UDIMMs per channel. UDIMMs should not be installed in slots Ch 1-I, Ch
2-J, Ch 3-K, or Ch 4-L.
•
HDIMMs require 12 DIMMs per processor.
•
When two processors are installed, install the DIMMs in sequential alphabetical order balanced
between the two processors: P1-A, P2-A, P1-B, P2-B, P1-C, P2-C, and so on.
For detailed memory configuration rules and guidelines, use the Online DDR3 Memory Configuration Tool
on the HP website (
http://www.hp.com/go/ddr3memory-configurator
).
DIMM speeds are supported as indicated in the following table.
Populated slots
(per channel)
Rank
Speeds supported (MT/s)
1
Single- or dual-rank
1333, 1600
1
Quad-rank
1333
2
Single- or dual-rank
1333
3
Single- or dual-rank
1066
Advanced ECC population guidelines
For Advanced ECC mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines.
•
DIMMs may be installed individually.
Online spare population
For Online Spare memory mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines.
•
Each channel must have a valid online spare configuration.
Содержание ProLiant DL380p
Страница 6: ...Contents 6 Acronyms and abbreviations 128 Documentation feedback 131 Index 132 ...
Страница 47: ...Hardware options installation 47 14 Install the heatsink 15 Remove the two fan blanks ...
Страница 61: ...Hardware options installation 61 o 8 or 16 drive SFF o 8 drive LFF ...
Страница 90: ...Cabling 90 Cabling SAS hard drive cabling SFF hard drive cabling SFF cabling with optional drive cage ...
Страница 91: ...Cabling 91 LFF hard drive cabling Optical drive cabling ...
Страница 92: ...Cabling 92 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Страница 97: ...Cabling 97 Connect the cable as indicated ...
Страница 126: ...Support and other resources 126 ...
Страница 127: ...Support and other resources 127 ...