Physical and operating specifications 91
Table 14
Physical Dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
12’’ x 13.5’’
Server dimensions
Rack
448W * 43H * 698.7D (mm)
Server weight
Basic Configuration ( excludes keyboard and monitor): 19 kg
Table 15
Environmental Specifications
Item
Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr c
LWad: 6.
7
Bels
(operating at room temperature)
LWad:
6.7
Bels
(Idle at room temperature)
Table 16
Non-Hot-Plug Power Supply Specifications
Item
Description
Dimensions (H x W x D)
40 mm x 106 mm x 270 mm
Weight (approximate)
1.85 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC /200 VAC to 240 VAC
Line frequency
50 – 60 Hz
Rated input current
5.5 –10 A
BTU rating
N/A
Содержание ProLiant DL160 G5P
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 82: ...Diagnostic tools and setup utilities 82 Security menu Figure 69 Security menu of the BIOS setup utility 1 ...