Removal and replacement procedures 38
Pre-Installation procedure
Perform the steps below before you open the server or before you remove or replace any component.
WARNING:
Failure to properly turn off the server before you open the server or before your start
installing/ removing components may cause serious damage as well as bodily harm.
1.
Turn off the server and all the peripherals connected to it.
2.
Unplug all cables from the power outlets to avoid exposure to high energy levels that may cause
burns when parts are short-circuited by metal objects such as tools or jewelry.
If necessary, label each one to expedite reassembly.
3.
Disconnect telecommunication cables to avoid exposure to shock hazard from ringing voltages.
4.
If server is installed in a rack, remove server and place it on a flat surface.
5.
Remove the top cover according to the instructions described in the System covers section in this
chapter.
6.
Remove the top middle cover according to the instructions described in the System covers section
in this chapter.
7.
Follow the ESD precautions listed previously in this chapter when handling a server component.
IMPORTANT:
To streamline the configuration process, read through the entire installation/removal
procedure first and make sure you understand them before you before you begin.
Post-installation instructions
Observe the following items after installing or removing a server component:
1.
Be sure all components are installed according to the described step-by-step instructions.
2.
Reinstall the rear cage, air baffle, peripherals, and system cables that you have removed.
3.
Reinstall the top cover.
4.
Reinstall the top middle cover.
5.
Reinstall server into rack.
6.
Connect all external cables and the AC power cord to the system.
7.
Press the power button on the front panel to turn on the server.
Server warnings and cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING:
The DL series is designed to operate in a typical server room; it only can be operated
by professional (or licensed) service person.
WARNING:
To reduce the risk of electric shock or damage to the equipment:
•
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
•
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
•
Unplug the power cord from the power supply to disconnect power to the equipment.
Содержание ProLiant DL160 G5P
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 82: ...Diagnostic tools and setup utilities 82 Security menu Figure 69 Security menu of the BIOS setup utility 1 ...