Diagnostic tools and setup utilities 87
Table 12
POST Error Messages
Error-Code
Error Message
Description / Corrective Action
04E
Primary Slave Hard Disk
Error
The IDE/ATAPI device configured as Primary Slave could not
be properly initialized by the BIOS. This message is typically
displayed when the BIOS is trying to detect and configure
IDE/ATAPI devices in POST.
04F
Secondary Master Hard
Disk Error
The IDE/ATAPI device configured as Secondary Master could
not be properly initialized by the BIOS. This message is
typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
050
Secondary Slave Hard Disk
Error
The IDE/ATAPI device configured as Secondary Slave could
not be properly initialized by the BIOS. This message is
typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
051
Master Hard Disk Error
The IDE/ATAPI device configured as Master in the 3rd IDE
controller could not be properly initialized by the BIOS. This
message is typically displayed when the BIOS is trying to
detect and configure IDE/ATAPI devices in POST.
052
Master Slave Disk Error
The IDE/ATAPI device configured as Slave in the 3rd IDE
controller could not be properly initialized by the BIOS. This
message is typically displayed When the BIOS is trying to
detect and configure IDE/ATAPI devices in POST.
603
System Fan 1 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
604
System Fan 2 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
605
System Fan 3 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
606
System Fan 4 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
607
System Fan 5 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
608
System Fan 6 Missing
System fan 1 is not installed, user should install the system
fan. The system will shut down.
60F
Fan Solution Not Sufficient!
Critical Failure Detected –
System Shutting Down in 15
Second!
The non-redundancy fan is not installed, user should install the
system fan. The system will shut down
601
BMC Not Responding
BMC not responding, you can load the optimal default value,
or you must change the LO100 card.
05E
Password check failed
If user input incorrect password more than three times, then
display this error information and continue to boot.
T
here are
two 'password checked failed'. 05E for setup password.
Checking NVRAM Update
Failed
BIOS could not write to the NVRAM block. This message
appears when the FLASH part is malfunctioning.
Содержание ProLiant DL160 G5P
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 82: ...Diagnostic tools and setup utilities 82 Security menu Figure 69 Security menu of the BIOS setup utility 1 ...