Removal and replacement procedures 39
4.
Remove the NAND flash module ("
NAND flash module for the Smart Array P220i Controller
" on page
Removing the SAS controller capacitor pack
" on page
) from the failed
server blade, and install the NAND flash module and capacitor pack in the recovery server blade.
5.
Power up the recovery server blade.
If data was saved on the NAND flash module, then a 1792 POST message appears, stating that valid
data was flushed from the cache. This data is now stored on the drives in the recovery server blade.
Front panel/drive cage assembly
To remove the component:
1.
Power down the server blade (on page
2.
Remove the server blade (on page
3.
Remove the access panel ("
" on page
CAUTION:
Always disconnect the drive cables from the SAS controller before removing the
DIMM baffle. Failure to do so may result in damage to the SAS controller.
4.
Disconnect the drive cables from the SAS controller and remove the DIMM baffle ("
" on
5.
Remove all hard drives ("
" on page
6.
Extend the serial label pull tab from the front of the server blade.
CAUTION:
Always disconnect the drive cable before removing the front panel/drive cage
assembly.
Содержание ProLiant BL465c Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 20: ...Illustrated parts catalog 20 ...