Removal and replacement procedures 55
10.
Install the heatsink ("
" on page
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
11.
Install all components removed from the failed system board.
12.
Install the front panel/hard drive cage assembly ("
Front panel/drive cage assembly
" on page
13.
Install all drives ("
" on page
IMPORTANT:
To avoid damage to the server blade, support the riser board when installing the
TPM board and rivet.
14.
If necessary, install the TPM module. For more information, see the
HP ProLiant BL465c Gen8 Server
Blade User Guide
.
15.
Install the access panel ("
" on page
After you replace the system board, you must re-enter the server blade serial number and the product ID.
1.
During the server blade startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warning appears:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.
7.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
8.
Enter the product ID and press the
Enter
key.
9.
Press the
Esc
key to close the menu.
10.
Press the
Esc
key to exit RBSU.