Removal and replacement procedures 44
10.
Install the heatsink.
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
11.
Install all components removed from the failed system board.
12.
Install the hard drive cage/bezel assembly ("
Hard drive cage/bezel assembly
13.
14.
Restore the serial label pull tab to the original position.
15.
Install the server blade.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
System Options
menu.
3.
Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
10.
Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.