Hood sensor
Description
Spare part number
Hood sensor
638816-001
1.
Prepare the computer for disassembly (
Preparation for disassembly on page 37
).
2.
Remove the access panel (
Access panel on page 38
).
3.
Disconnect the cable from the system board connector labeled HSENSE
(1)
.
4.
Using a tool, remove the sensor from the slot by pushing it into the computer to remove it
(2)
.
To install the hood sensor, reverse the removal procedure.
Hood sensor
77