![HP ProCurve 8116fl Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/hp/procurve-8116fl/procurve-8116fl_installation-and-getting-started-manual_162861044.webp)
Inst
alli
ng t
he Pro
C
u
rve
Switch 8100fl
Installing the ProCurve Switch 8100fl
Installation Procedures
Installing a Switch Fabric Module
A ProCurve Switch 8100fl requires at least one switch fabric module to process
traffic for any interface module. Only one switch fabric module is required for
full throughput.
Note that the 8-slot Switch 8108fl uses the half-height switch fabric module.
The 16-slot Switch 8116fl uses a full-height switch fabric module.
If you are installing two switch fabric modules, the primary switch fabric
module is the one installed in slot
FM-A
. The redundant switch fabric module
is the module installed in slot
FM-B
.
C a u t i o n
To prevent equipment damage, review the installation precautions on
To install a switch fabric module
(J8729A or J8730A)
:
1. If a cover plate is installed in the switch fabric module slot, remove it by
loosening the captive screws (using slotted or P2 Phillips screwdriver)
and pulling the ejectors.
2. Open the ejectors at the top and bottom of the module, and hold the upper
ejector lever in the unlocked position while you are installing the module
(see step 1 in the illustration opposite).
3. Position the switch fabric module in the
FM-A
slot (for primary module)
or
FM-B
slot (for redundant module). (You can use either slot in a single
switch fabric module installation.)
4. Slide the switch fabric module all the way into the slot, firmly but gently
pressing to make sure that the pins on the back of the module are
completely seated in the backplane.
C a u t i o n
The 8116fl switch fabric module is a double height module, which makes
it heavier than the other modules. Make sure that the module is properly
seated when you insert it in the switch chassis.
Make sure that the metal plate of the module, and not the circuit board,
is between the guides. Check both the upper and lower guides for proper
alignment.
Do not force a module into its slot
. If the module does not seem to be
seating correctly, ease it back out and check alignment. Forcing a module
can damage it and the chassis.
5. To lock the module into the slot, close the ejectors until they are vertical.
2-18
Содержание ProCurve 8116fl
Страница 1: ...Installation and Getting Started Guide ProCurve Series 8100fl Switches www procurve com ...
Страница 2: ......
Страница 3: ...ProCurve Series 8100fl Switches Installation and Getting Started Guide ...
Страница 10: ... This page is intentionally unused ...
Страница 26: ... This page is intentionally unused ...
Страница 60: ... This page is intentionally unused ...
Страница 72: ... This page is intentionally unused ...
Страница 88: ... This page is intentionally unused ...
Страница 117: ...Safety and Regulatory Statements Safety Information China Safety Information China Safety and Regulatory Statements C 7 ...
Страница 122: ... This page is intentionally unused ...
Страница 133: ......