HP ProCurve 8116fl Скачать руководство пользователя страница 1

Installation and Getting 
Started Guide 

ProCurve Series 8100fl Switches 

www.procurve.com 

Содержание ProCurve 8116fl

Страница 1: ...Installation and Getting Started Guide ProCurve Series 8100fl Switches www procurve com ...

Страница 2: ......

Страница 3: ...ProCurve Series 8100fl Switches Installation and Getting Started Guide ...

Страница 4: ... of this material The only warranties for ProCurve Networking products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty ProCurve Networking shall not be liable for technical or editorial errors or omissions contained herein Hewlett Packard assumes no responsibility for the...

Страница 5: ...ule LEDs 1 6 Switch Fabric Module LEDs 1 7 Interface Module LEDs 1 8 Back of the Switch Power Connectors 1 13 ProCurve Switch 8100fl Features 1 14 2 Installing the ProCurve Switch 8100fl Parts and Part Numbers 2 1 Switch 8108fl J8727A 2 1 Switch 8116fl J8728A 2 2 Additional Parts 2 3 Installation Procedures 2 4 Summary 2 4 Installation Guidelines 2 5 1 Preparing the Installation Site 2 7 Cabling I...

Страница 6: ...roCurve Intelligent EDGE Devices 2 32 Expanding Your Network 2 33 3 Getting Started With Switch Configuration Booting Up and Accessing the CLI 3 1 Setting Basic System Information 3 2 Setting the Management Module IP Address 3 2 Saving and Using the New Configuration 3 4 Setting the System Date and Time 3 4 Setting System Parameters 3 5 Setting the Host Name 3 5 Setting System ID Location and Cont...

Страница 7: ...nstalling Transceivers 4 9 Removing Transceivers 4 10 Optional Installing an Optical Media Converter 4 10 Connecting Network Cables to Transceiver Ports 4 11 Replacing Mini GBICs 4 12 Removing Mini GBICs 4 12 Installing mini GBICs 4 15 5 Troubleshooting Basic Troubleshooting Tips 5 1 Troubleshooting Procedures 5 3 Hardware Diagnostic Tests 5 6 Resetting the Switch 5 6 Testing Twisted Pair Cabling ...

Страница 8: ...ectrical A 4 Environmental A 4 Acoustic A 4 Safety and Regulatory A 4 B Switch Ports and Network Cables Switch Ports and Connectors B 1 Twisted Pairs B 1 Fiber Optic B 1 Cables B 2 Twisted Pair Cables B 2 Fiber Optic Cables B 3 CX4 Copper Cables B 4 Twisted Pair Cable Connector Pin Outs B 5 Straight Through Twisted Pair Cable for 10 100 Mbps Network Connections B 6 Cable Diagram B 6 Pin Assignment...

Страница 9: ...ormations concernant la sécurité C 2 Hinweise zur Sicherheit C 3 Considerazioni sulla sicurezza C 4 Consideraciones sobre seguridad C 5 Safety Information Japan C 6 Safety Information China C 7 EMC Regulatory Statements C 8 U S A C 8 Canada C 8 Australia New Zealand C 8 Japan C 8 Korea C 9 Taiwan C 9 Regulatory Model Identification Number C 9 Regulatory Information China C 11 D Waste Electrical an...

Страница 10: ... This page is intentionally unused ...

Страница 11: ...ports security and convergence decisions at the edge of your network The ProCurve Series 8100fl switches include the Switch 8108fl and the Switch 8116fl This chapter describes both switches including Front and back of a switch Hardware and software features see page 1 14 for details ProCurve Switch 8108fl J8727A Switch 8116fl 16 Interface Module slots Up to 160 100 1000 T ports Up to 160 Gigabit f...

Страница 12: ...Grounding Port Fan Status LED Power Status LEDs Switch Fabric Modules Management Modules Interface Modules Slots 1 4 and 5 8 in the Switch 8108fl Slots 1 8 and 9 16 in the Switch 8116fl This illustration shows a Switch 8108fl but the labeling and descriptions also apply to the taller Switch 8116fl Not e In a Switch 8116fl the switch fabric module is sized differently Otherwise all hardware compone...

Страница 13: ...xcept for the full height slot cover for the 8116fl switch fabric module Half height slot covers have different widths switch fabric modules are wider than interface modules C a u t i o n Failure to cover empty slots while the system is running degrades the forced air cooling system and can cause the system to overheat Backplane The backplane is installed at the factory and occupies the rear of th...

Страница 14: ... single switch fabric module you can install the module in either slot Not e The 8108fl switch fabric module and 8116fl switch fabric module are not interchangeable You can install the half height module only in the 8108fl Switch the 8116fl Switch requires a full height switch fabric module Management Module A ProCurve Switch 8100fl requires at least one primary management module to operate You ca...

Страница 15: ...gabit LX LC mini GBIC J4859B ProCurve Gigabit LH LC mini GBIC J4860B ProCurve Gigabit 1000Base T mini GBIC J8177B ProCurve Switch fl 1 Port X2 10GbE Module J8736A ProCurve Switch fl 2 Port X2 10GbE Module J8737A that uses and supports the following transceivers as of this printing 10 Gigabit X2 SC SR Optic transceiver J8436A 10 Gigabit X2 SC LR Optic transceiver J8437A 10 Gigabit X2 SC ER Optic tr...

Страница 16: ...EDsontheRJ 45 portshowingnetworkconnections The LED states are described in the following table Table 1 1 Management Module J8731A LEDs Management Module LED Color State Meaning PCMCIA Card Slot Active Green Green n a Flashing Solid Off Negotiating active backup management module s during boot sequence Module is active normal Module is in back up mode 10 100 Base T Port RJ 45 Status n a Green Gree...

Страница 17: ...ftware releases Switch Fabric Module LEDs Switch fabric modules have two LEDs an Active LED on top and a Status LED on bottom The LED states are described in the following table Table 1 2 Switch Fabric Module J8729A J8730A LED Switch Fabric Module LEDs LED Color State Meaning Active Green Green n a Flashing Solid Off Negotiating active backup switch fabric module s during boot sequence Module is a...

Страница 18: ...ashing Transmitting data Link is up no data is being transferred When no connector is plugged into the port the LED will flash approximately onceeveryfewseconds Thison offcycle is a safety feature known as Auto Laser Shutdown Link Green n a Solid Off Link is up No connector is plugged into the port Status LED Status n a Green Green Yellow Orange Off Flashing Solid Flashing No power to the module M...

Страница 19: ...er port Link per port Green Amber n a Solid Solid Off Port is in 1000 Mbps mode Port is in 100 Mbps mode No connector is plugged into the port Ports 5 6 Activity per port Green n a Flashing Off Transmitting data No data is being transferred and or no connector is plugged into the port Ports 7 10 Status LED Status n a Green Green Yellow Orange Off Flashing Solid Flashing No power to the module Modu...

Страница 20: ...ta Link is up no data is being transferred When no connector is plugged into the port the LED will flash approximately once every four seconds This is a safety feature known as Auto Laser Shutdown Ports 5 8 Link per port Green n a Solid Off Link is up No connector is plugged into the port Ports 9 10 Status LED Status n a Green Green Yellow Orange Off Flashing Solid Flashing No power to the module ...

Страница 21: ...ecs and then Off A transceiver has been correctly inserted into the transceiver port After the insertion test the LEDs will remain Off until a network cable is inserted into the transceiver and the LEDs follow their normal operational behavior Link Activity and Status all module LEDs together Orange Green Off Solid Orange 0 5 secs then Solid Green 1 5 secs and then Off The module is receiving init...

Страница 22: ...f Solid Orange 0 5 secs then Solid Green 1 5 secs and then Off A transceiver has been correctly inserted into the transceiver port After the insertion test the LEDs will remain Off until a network cable is inserted into the transceiver and the LEDs follow their normal operational behavior Link Activity and Status all module LEDs together Orange Green Off Solid Orange 0 5 secs then Solid Green 1 5 ...

Страница 23: ...iefopeningfor power cord AC power receptacles ProCurve 8100fl switches have power connections on the back at the bottom of the chassis Use the strain relief opening to tie wrap the power cable Not e If necessary attach the power cables before installing the chassis in the rack Introducing the ProCurve Series 8100fl Switch 1 13 ...

Страница 24: ... switching capacity in each switch fabric module 80Gbps system throughput Switch 8116fl 320Gbps aggregate switching capacity in each switch fabric module 160Gbps system throughput Up to 238 million packets per second non blocking routing throughput Full duplex operation on all ports Easy management of the switch through the following interfaces Simple Network Management Protocol SNMP v1 v2 Full fe...

Страница 25: ...ic from specific ports Port trunking for higher switch to switch throughput and link level redundancy with support for standards based link aggregation 802 3ad 802 1s Multi Instance Spanning Tree Protocol to eliminate network loops 802 1Q compliant VLANs to divide the attached end nodes into logical groupings to suit your business needs Layer 3 routing functionality IP static routes Routing Intern...

Страница 26: ... This page is intentionally unused ...

Страница 27: ... on page 2 5 for additional safety considerations when handling this product Parts and Part Numbers Not e The following components are the same in both the Switch 8108fl and the Switch 8116fl Power supplies Fan trays Management module Interface modules The switch fabric modules however are different in each model Switch 8108fl J8727A The ProCurveSwitch8108flisshipped in severalcontainerswiththe fo...

Страница 28: ...iwan 8121 0968 Continental Europe 8120 6352 Thailand 8121 0675 Denmark 8120 6897 United Kingdom Hong Kong Singapore 8121 0907 Israel 8121 1010 United States Canada Mexico 110V 8120 6894 Japan 8121 0942 United States Canada Mexico 220V 8120 8651 South Africa 8121 0915 J a p a n P o w e r C o r d Wa r n i n g Please use the attached power cable The attached power cable is not to be used with any oth...

Страница 29: ...10V 8120 6894 Japan 8121 0942 United States Canada Mexico 220V 8120 8651 South Africa 8121 0915 J a p a n P o w e r C o r d Wa r n i n g Please use the attached power cable The attached power cable is not to be used with any other products Additional Parts Depending on your order s specifications your shipment may also contain some or all of the following additional parts ProCurve Switch 8108fl Re...

Страница 30: ...removing all hardware components such as all module blanks power supplies fan trays and so on from the chassis before moving and installing it in a rack 3 Installing fan trays page 2 15 ProCurve 8100fl switches come with two fan trays to provide cooling for the switch The fan tray assembly is located above the power supply just below the vertical module slots 4 Installing modules page2 16 Thereare...

Страница 31: ...est device at the bottom and progressively lighter devices installed above The rack or cabinet must be adequately secured to prevent it from becoming unstable and or falling over High leakage current can be caused by multiple power supplies For this reason ensure that each power supply is connected to a separate branch circuit with a proper earth connection before you connect it The grounding scre...

Страница 32: ... To power on and off the switch connect and disconnect the power supply cable or remove all power supplies Ensure that the socket outlet is located installed near the equipment and is easily accessible in case the switch must be powered off To avoid electrical shock disconnect all power supply cables before servicing equipment Ensure the switch does not overload the power circuits wiring and over ...

Страница 33: ...oCurve Switch 8100fl Fiber Optic Cables 10 PortMini GBIC Gigabit SX Multimode fiber optic cables fitted with LC 220 meters to 550 meters Interface Module on Gigabit SX connectors depending on the cable used J8735A LC mini GBIC For more information see Fiber Optic Cables on page B 3 Gigabit LX on Gigabit LX LC mini GBIC Single modefiber opticcablesfittedwithLC connectors The multimode cables specif...

Страница 34: ...ng diameter 1550 nm single mode cable 2 30 low metal content single mode fiber optic kilometers 40 kilometers on cables complying with the ITU T G 652 and an engineered fiber optic link ISO IEC 793 2 Type B1 standards that meets standards in the specification OMC CX4 Fiber 12 fiber 50 125 μm core cladding diameter 1 300 meters Optical Media multimode Fiber ribbon cable 12 fiber 62 5 Converter for ...

Страница 35: ...id personal injury plan on having at least three people available to help move the unit into place onto the rack THREE OR MORE PEOPLE ARE REQUIRED WHEN MOUNTING THIS SWITCH C a u t i o n s Follow these safety precautions before you move the switch ProCurve Networking recommends that you use a rack shelf not provided to help mount a switch as described in this section If you do not have a rack shel...

Страница 36: ...s into position in front of the rack using a trolley not shipped with the switch Position the chassis so that the front of the switch is facing towards you This will allow you to easily slide the chassis into place 4 Optional Install a rack shelf not provided with your switch into position as low as possible in the rack Make sure that any screws used to secure the shelf to the rack are securely ti...

Страница 37: ...the rack see illustration below Attach the brackets on both sides of the chassis for the position you select Be sure to tighten the mounting screws until they are snug Be careful not to overtighten them This can result in damage to the screws or chassis Installing the ProCurve Switch 8100fl Mounting Screws Mounting Screws Left Rack Mounting Bracket Right Rack Mounting Bracket 2 11 ...

Страница 38: ...chassis lines up with the front edge of the sling see illustration below This allows the back of the chassis to extend over the sling so that it can be more easily positioned in the rack or on the rack shelf Product Sling 7 With the help of a second person or hand crane lift the chassis into position in front of the rack or set its back edge on top of a rack shelf 2 12 ...

Страница 39: ...lp of a third person carefully slide the chassis into the rack over the rack shelf if one is installed until the mounting brackets touch the rack and you can remove the product sling The chassis may lean slightly backwards in the rack Installing the ProCurve Switch 8100fl 2 13 ...

Страница 40: ... the lowest holes of the mounting brackets on the chassis to the rack Continue tightening the screws in the holes on the right and left sides of the mounting brackets to fix it to the rack starting with the bottommost holes and moving upwards WARNING All mounting screws must be tightened securely before the chassis can be loaded with additional hardware If you accidentally leave the screws loose t...

Страница 41: ... clearance to add or remove modules To install a fan tray 5069 7936 1 Align the fan tray guides with its corresponding slot and push in until the fan tray mounting plate contacts the chassis frame Fan Tray one of two 1 Slide fan tray completely into chassis 2 Tighten retaining screws to secure 2 Tighten the two screws on each side of the fan tray housing using a slotted or Phillips screw driver Ha...

Страница 42: ...Management modules thicker half height modules are installed in slots labeled MM If you are installing only one management module you can install it in either slot MM A or MM B If you are installing two management modules the primary management module is the one installed in slot MM A The redundant management module is the module installed in slot MM B Interface modules narrow half height modules ...

Страница 43: ...y close to contacting the front face of the switch chassis Do not force a module into its slot If the module does not seem to be seating correctly ease it back out and check alignment Forcing a module can damage it and the backplane Modules are keyed so that they cannot be fully installed in a wrong slot Check for alignment Make sure that the metal plate of the module not the circuit board is betw...

Страница 44: ... the ejectors at the top and bottom of the module and hold the upper ejector lever in the unlocked position while you are installing the module see step 1 in the illustration opposite 3 Position the switch fabric module in the FM A slot for primary module or FM B slot for redundant module You can use either slot in a single switch fabric module installation 4 Slide the switch fabric module all the...

Страница 45: ...s 3 Rotate ejectors to lock the module in place and then tighten the captive screws Switch Fabric Module Metal Plate Module Guides The module must be fully seated and the ejectors fully locked vertical before the captive screws will align properly Also fully seating the module ensures proper contact of the card with the backplane which is necessary for optimal performance Repeat steps 1 to 6 to in...

Страница 46: ... in the management module slot MM A or MM B remove the cover plate loosen the captive screws on the ejectors until the screws pop out then open the ejectors and pull out the plate 2 Open the ejectors at the top and bottom of the module and hold the upper ejector lever in the unlocked position while you are installing the module see step 1 in the illustration opposite 3 Align the metal plate of the...

Страница 47: ... central slots 3 Pushinejectorsinto secure and tighten captive screws 1 Pulloutupperejector lever to hold it in unlocked position Management Module Metal Plate Module Guides C a u t i o n The management module must be fully seated and the ejectors fully locked vertical before the captive screws will align properly Also fully seating the card ensures proper contact of the card with the backplane wh...

Страница 48: ...talled in the interface module slot remove the cover plate loosen the screws on the ejectors then open the ejectors and pull out the plate 2 Open the ejectors at the top and bottom of the module and hold the upper ejector lever in the unlocked position while you are installing the module see step 1 in the illustration opposite 3 Align the metal plate of the interface module between the module guid...

Страница 49: ...oval by unauthorized personnel 2 Install interface modules in any of the numbered slots on the left and right side of the chassis 3 Rotate ejectors to lock the module in place and then tighten the captive screws Interface Module Metal Plate Module Guides The interface module must be fully seated and the ejectors fully locked vertical before the captive screws will align properly Also fully seating...

Страница 50: ... before turning the power on to verify the installation see page 2 29 C a u t i o n s Observe the following precautions when installing a power supply in your switch Take into consideration the ratings on power supplies when connecting themtoyoursupplycircuits Overloadingcircuitscandestroyovercurrent protection as well as supply wiring Use a single phase grounded AC power source located within 6 f...

Страница 51: ...roximate 45 degree angle AC Power Supply 3 To lock the power supply in place adjust the handlepositionattheedgeofthechassis andthen rotate the handle upwards to engage retaining 3 Slide the AC power supply all the way into the slot firmly but gently pressing to make sure that the connectors on the back of the power supply are completely seated in the backplane 4 Push the handle up and flush with t...

Страница 52: ...om of the chassis as your installation requires see the following illustration Installing the ProCurve Switch 8100fl AC Power Receptacles Grounding Screws To provide strain relief for a power cable tie wrap the cable to the access opening on the side of the chassis or to the rack 6 Repeat steps 1 to 5 to install an additional power supply 2 26 ...

Страница 53: ...lator This method requires that you configure the switch with an IP address and a subnet mask by using either out of band console access or through DHCP Bootp ProCurve 8100fl switches can support simultaneous out of band console and in band Telnet sessions Terminal Configuration To connect a console to the switch configure the PC terminal emulator as a VT 100 or ANSI terminal or use a VT 100 termi...

Страница 54: ...age Press any key to continue Press a key and you willthensee the switch console CLI prompt Telnet Console Access To access the switch through a Telnet session follow these steps 1 Ensure the switch is configured with an IP address as described in Setting the Management Module IP Address on page 3 2 and that the switch is reachable from the Telnet workstation for example by using a Ping command to...

Страница 55: ...l the appropriate slot covers over any unused power bays and module slots Failure to use the correct slot cover may result in improper switch cooling Make sure that you use the correct type of cover for each empty slot Each cover is labeled as follows to indicate the type of slot for which it is designed part numbers shown in parentheses FM Cover for Switch 8008fl fabric module slots 5069 0122 FM ...

Страница 56: ...rving the LEDs Make sure the LED on each power supply and fan tray assembly is a solid green Also make sure that the Status LED on each active module is solid green N o t e s o n L E D s The Link and Activity LEDs on the X2 10 GbE modules J8736A and J8737A will go on for two seconds when a transceiver is inserted into the port They will then go off until a network cable is plugged into the transce...

Страница 57: ...bleshooting the Link LED Condition Diagnostic Tip Port Link LED is For the indicated port verify that both ends of the cabling at the switch and the connected off when a cable is device are securely connected connected Verify that the connected device and switch are both powered on and operating correctly Verify that you have used the correct cable type for the connection for more information on c...

Страница 58: ...ligent edge devices The ProCurve Switch 8100fl series provides an alternative to traditional core routing switches by combining low cost and complexity with high availability resiliency and forwarding capacity ProCurve 8100fl Switches connected by a 10GbE Link PCs and peripherals Serversconnected by Gigabit links Wireless Clients Intelligent Edge Switches WAN Router The 8100fl architecture is desi...

Страница 59: ...ch connected to a traditional core network using a 10 GbE link for maximum throughput Installing the ProCurve Switch 8100fl ProCurve 8100fl Switches Connected to Core Routers by a 10GbE Link PCs and peripherals Serversconnected by Gigabit links Wireless Clients Intelligent Edge Switches ProCurve 8100fl switches can extend the traditional core network by providing additional bandwidth and decision ...

Страница 60: ... This page is intentionally unused ...

Страница 61: ...tly through a remote Telnet session For more information refer to the Management and Configuration Guide which is on the Documentation CD ROM that came with your switch Booting Up and Accessing the CLI 1 Connect a terminal device to the switch as described on page 2 27 2 Power on the switch by either inserting the power supplies or turning on the AC to the power supplies 3 At the prompt press Ente...

Страница 62: ...his section assumes a basic understanding of CLI commands modes and procedures For more detailed information refer to the Management and Configuration Guide on the Documentation CD ROM that comes with your switch The running configuration remains in effect only during the current power cycle If you power off or reboot the switch without saving the running configuration changes to the Startup confi...

Страница 63: ...anagement ip address ipaddr ip address 10 10 1 45 255 255 248 0 ip address 10 10 1 45 21 Switch 8100fl config interface management no shutdown Switch 8100fl enable Switch 8100fl configure Switch 8100fl config interface management0 Switch 8100fl config interface management ip address 10 10 1 45 255 255 248 0 Switch 8100fl config interface management no shutdown 6 From Configuration mode enter the f...

Страница 64: ...interface Management0 no shutdown ip address 10 10 1 45 21 ip telnet no shutdown line vty 0 line vty 1 line vty 2 end 2 To save the configuration changes from the running configuration to the startup configuration file enter the write memory command Switch 8100fl config write memory The switch reinstates all configuration changes for the next reboot Setting the System Date and Time To set the syst...

Страница 65: ... example to enter the hostname PNB8108 type the following Switch 8100fl config hostname PNB8108 Setting System ID Location and Contact To assign a chassis ID a physical location and a contact person to the system using snmp Simple Network Management Protocol enter the following commands Switch 8100fl config snmp location string Switch 8100fl config snmp chassis id string Switch 8100fl config snmp ...

Страница 66: ...US can be found in the Management and Configuration Guide Specifying the CLI level Password To add password protection to the CLI enter the following command Switch 8100fl config enable secret password By default the password you enter will be encrypted to prevent it from being displayed in clear text in the configuration file output For example To create an encrypted password called mysecretpassw...

Страница 67: ...gn line level passwords To prevent unauthorized access itisrecommendedyouassignline levelpasswordprotectiontoalltheterminal lines that you configure To add password protection to each terminal or console line 1 From Configuration mode enter the following command Switch 8100fl config line vty 0 where 0 represents the line number of the vty terminal line connection 2 Enter the following command to c...

Страница 68: ...t you have configured on the switch Recovering from Forgotten Passwords If you forget your line level passwords you can log on using the console and enter new passwords Once you enter the new passwords other users who access these lines can use the new passwords To make the changes permanent save the new passwords to the startup configuration If you forget your console or CLI level password that a...

Страница 69: ...and Not e If you have removed a backup management module insert it back into its slot before entering write memory this will synchronize both active and backup startup configurations to use the new password The next time you reboot the system you will be able to use the new password for access and authentication Enabling Secure Shell SSH Access To enable an ssh connection to the switch 1 From conf...

Страница 70: ...k on Switches to go to the page that has the software updates for your switch 4 Click on the software version number that you require and then follow the instructions to download the software Check Software Versions To determine whether you have the latest software installed you can compare the software version that is available on the web site with the version that is currently installed on your ...

Страница 71: ...h 8100fl copy tftp 10 28 227 103 CY 02 00 swi flash The new image file will be copied to primary flash 4 Use the image install command to install the image in a backup software storage bank Switch 8100fl image install name where name is the path or filename for example flash CY 02 00 swi The new software is loaded in the flash memory bank opposite the bank that is currently active For instance if ...

Страница 72: ... This page is intentionally unused ...

Страница 73: ...le and or management module The hot swapping feature allows you to remove or install modules without powering off or rebooting the switch Swapped in modules are recognized by the switch and begin functioning immediately after they are installed C a u t i o n The ProCurve 8100fl Switch and its components are sensitive to static discharge Use an antistatic wrist strap and observe all static precauti...

Страница 74: ...Not e The Switch 8116fl chassis requires at least two active power supplies operating to function correctly To remove an AC power supply 1 Ensure that the AC power supply is not plugged into an AC power source 2 Insert a flat blade screwdriver or similar lever device into the indent located on the bottom edge in the center of the handle 3 Gently turn the screwdriver with the handle downward and lo...

Страница 75: ...bly out one inch and allow the fans to stop rotating before pulling it all the way out To replace a fan tray 1 Remove the two screws holding the failed fan tray assembly The LED on the fan tray and on the chassis will indicate which one is failed 2 Pull the fan tray assembly out 3 Install the new fan tray assembly as described on page 2 15 Not e In case your cabling installation does not allow acc...

Страница 76: ...can be removed or installed while the switch is powered on However note the following differences between module types with respect to redundancy When the primary switch fabric module fails the redundant switch fabric module takes over in less than five seconds and continues to function as the primary module even after the failed module is replaced When hot swapping interface and switch fabric mod...

Страница 77: ...module and interface modules During this time service is affected To perform a controlled shutdown on a management or fabric module and cause the redundant module to take over enter the following command Switch 8100fl config halt slot You can also perform a controlled shutdown on a module by entering the following command Switch 8100fl config power down slot Not e To display a list of the slot num...

Страница 78: ...etal body Take appropriate care when removing interface modules from the ProCurve 8100fl Switch They may be hot to the touch The ProCurve 8100fl Switch modules have low force high performance connectors High insertion forces are not necessary to install the modules and should not be used Ensure you fully insert the modules That is press the module into the slot until the bulkhead on the module is ...

Страница 79: ... ejector levers until they are vertical to seat the module fully in place ensuring that the pins on the back of the module are completely connected to the backplane C a u t i o n Ensure that the backsheet metal plate of the interface module and not the circuit board is between the module guides Check both the upper and lower guides 3 Tighten the captive screws on each side of the module to secure ...

Страница 80: ...oval of the system image while the system is running 2 Insert the Compact Flash and snap it into place The Compact Flash is keyed so it only goes in one way See the following illustration for details 2 Snap bail over card to retain in place 1 Insert Compact Flash card into slot Management Module CompactFlash Memory card DIMM Slots 2 CompactFlash Memory card PCMCIA Card Slot 3 Reinstall the managem...

Страница 81: ...l a transceiver 1 Remove the port cover on the transceiver slot by squeezing the metal tabs together 2 Slide the transceiver into the empty slot until it stops Bail Copper Transceiver Fiber Optic Transceiver 3 Push firmly until you hear a click and the gasket seat against the bulkhead Not e When switch power is on the Link and Activity LEDs will come on for approximately two seconds and then go of...

Страница 82: ...an be installed into the copper transceiver to enable a fiber optic cable connection Not e You can install a media converter without having to power off the switch Use only the ProCurve supported media converter see page 1 5 To install a media converter 1 Connect the media converter to the copper transceiver port until it clicks into place Extractor Handle Copper Transceiver Optical Media Converte...

Страница 83: ...cable Aligning thecableconnectorswiththe slots ofthetransceiverports press the cable connector into the transceiver port until it snaps into place Optical Media Converter Fiber Optic Transceiver Not e To ensure proper transmit receive connections make sure the transmit from one device is connected to the receive of the other device To install copper cable 1 Insert the copper cable connector into t...

Страница 84: ...king Sales and Service Office or authorized dealer Removing Mini GBICs WARNING The ProCurve fiber optic mini GBICs are Class 1 laser devices Avoid direct eye exposure to the beam coming from the transmit port The extraction process varies among different mini GBICs see the illustrations and examples in this section The mini GBIC removal process is essentially to disengage the unit from its port vi...

Страница 85: ...lease from the switch you can see it move outward slightly 3 Pull the mini GBIC from the slot 4 If the device is not defective disposable insert a dust plug to protect it mini GBIC with plastictaborcollar InstalledPosition Release Remove ProCurve mini GBIC Socket releases Locking tab Release tab ProCurve mini GBIC 1 Pullreleasetabinto unlatch Locking tab from socket 2 Remove from socket ProCurve m...

Страница 86: ... Using the bail pull the mini GBIC from the slot 4 If the mini GBIC is not defective disposable protect it by inserting a dust plug mini GBIC with wire bail release ProCurvemini GBIC InstalledPosition Locking tab Socket Bail Release Locking tab releases from socket ProCurvemini GBIC 1 Pull bail out to unlatch Remove ProCurvemini GBIC 2 Remove from socket Replacing Hardware 4 14 ...

Страница 87: ...the receptacle until it locks into position C a u t i o n If the mini GBIC does not go in easily do not force it If the mini GBIC is not oriented properly it will stop about one quarter of the way into the slot remove and reorient the mini GBIC so that it slides easily into the slot Keep the dust plug in the mini GBIC when there is no fiber cable plugged in The optics will not work properly when o...

Страница 88: ... This page is intentionally unused ...

Страница 89: ...when starting your troubleshooting Faulty or loose cables Look for loose or obviously faulty connections If they appear to be OK make sure the connections are snug If that does not correct the problem try a different cable Non standard cables Non standard and miswired cables may cause network collisions and other network problems and can seriously impair network performance Use a new correctly wir...

Страница 90: ...nd Link Aggregation see the Management and Configuration Guide on the documentation CD ROM that came with your switch Check the port configuration A port on your ProCurve Switch 8100fl may not be operating as you expect because it has been put into a blocking state by Spanning Tree or LACP automatic link aggregation Note that the normal operation of the Spanning Tree and LACP features may put the ...

Страница 91: ...AN dealer or use the electronic support services from ProCurve Networking to get assistance See the Customer Support Warranty card for more information The fan module is not active Check the power cable and the circuit to which the power supply is connected If the green status LED on the power supply indicates that it is active immediately power down the chassis unplug the power supply and contact...

Страница 92: ...link on the ProCurve Networking web site at www procurve com Firstverify the switch hasa versionofcode thatsupports the module that is indicating the fault If the module is not one of the ones listed on page 1 14 check the module documentation to see what version of switch code is needed Download the new code and retest the module If you have the correct code installed in the switch try removing a...

Страница 93: ...the Configuration mode Configuration changes do not seem to be taking effect Use the procedure in Saving and Using the New Configuration on page 3 4 to activate the changes Configurationchangesare not reinstated after a reboot Use the procedure in Saving and Using the New Configuration on page 3 4 to save the configuration changes to the Startup configuration file The Series 8100fl Switch is not r...

Страница 94: ...oad option cause the switch to perform a power on self test which almost always will resolve any temporary operational problem Neither of these reset procedures causes any changes to the switch configuration Testing Twisted Pair Cabling If you think the cable should work but still isn t working it may not be compatible with the IEEE 802 3 Type 10Base T 100Base T or 1000Base T standards as appropri...

Страница 95: ...ent and Configuration Guide that is on the documentation CD ROM that came with your switch for more information These tests can also be performed from an SNMP network management station running a program that can manage the switch for example ProCurve Manager or ProCurve Manager Plus Testing End to End Network Communications Both the switch and the cabling can be tested by running an end to end co...

Страница 96: ...nectivity issues Ifthe switchhas avalidconfiguration andyouare restoringthefactory default settings for a reason other than configuration problems you should save the switch configuration prior to performing the factory default reset Then after the reset and resolution of the original problem you can restore the saved configuration to the switch For both the save and restore processes you can use ...

Страница 97: ...ce both with services that they offer and with services offered by ProCurve Networking Before Calling Support Before calling your networking dealer or ProCurve Networking technical support to make the support process most efficient first retrieve the following information Information Item Information Location Product identification including the chassis modules and mini GBICs Onthefrontoftheswitch...

Страница 98: ...h 8100fl Series new code can be downloaded to the switch through several methods for product enhancements and new features Please see the Management and Configuration Guide that is on the documentation CD ROM that came with your switch for more information New code is available on the ProCurve Networking web site at www procurve com ...

Страница 99: ...Port 100 1000 T Interface Module 10 Port mini GBIC Interface Module 1 Port X2 10 GbE Interface Module 2 Port X2 10 GbE Interface Module Interface Module Slot Cover Management Module Slot Cover Switch Fabric Module 8008fl Slot Cover Mounting Bracket each 43 9 cm 17 3 in 54 6 cm 21 5 in 57 7 cm 22 7 in 42 5 kg 93 8 lbs 99 7 kg 219 7 lbs 60 1 kg 132 5 lbs 4 7 kg 10 4 lbs 3 3 kg 7 3 lbs 1 3 kg 2 8 lbs...

Страница 100: ... 104 F 40 C to 70 C 40 F to 158 F Relative humidity 15 to 80 40 C 24 hours 90 65 C 12hours non condensing Maximum altitude 3 0 Km 10 000 ft 4 6 Km 15 000 ft Acoustic Acoustic sound pressure LpAm 63 6dB Acoustic sound power LWAd 80dB per ISO 7779 Safety and Regulatory FCC Rules Part 15 subpart B Class A ICE 003 Canadian Radio Interference Regulations Class A EN 55022 CISPR 22 Class A EN55024 EN 610...

Страница 101: ...g 7 3 lbs Blank Power Supply 1 3 kg 2 8 lbs Management Module 2 9 kg 6 4 lbs Switch Fabric Module 8116fl 6 3 kg 13 9 lbs 1 Port 10 GbE LR Interface Module 3 4 kg 7 4 lbs 10 Port 100 1000 T Interface Module 3 0 kg 6 7 lbs 10 Port mini GBIC Interface Module 3 1 kg 6 8 lbs 1 Port X2 10 GbE Interface Module 3 4 kg 7 4 lbs 2 Port X2 10 GbE Interface Module 3 4 kg 7 4 lbs Interface Module Slot Cover 1 5...

Страница 102: ... 104 F 40 C to 70 C 40 F to 158 F Relative humidity 15 to 80 40 C 24 hours 90 65 C 12hours non condensing Maximum altitude 3 0 Km 10 000 ft 4 6 Km 15 000 ft Acoustic Acoustic sound pressure LpAm 63 6dB Acoustic sound power LWAd 80dB per ISO 7779 Safety and Regulatory FCC Rules Part 15 subpart B Class A ICE 003 Canadian Radio Interference Regulations Class A EN 55022 CISPR 22 Class A EN55024 EN 610...

Страница 103: ...nd the single 10 100Base T Ethernet port on the management module accept 100 ohm differential unshielded and shielded twisted pair cable with RJ 45 connec tors as described on page B 2 The 1000Base T RJ 45 connectors on the 1000Base T mini GBIC J8177B are compatible with the IEEE 802 3ab 1000Base T standards and accept 1000 Mbps cables as described in page B 2 Fiber Optic The LC type connector por...

Страница 104: ...s long as all four pairs are connected But for the most robust connections you should use cabling that complies with the Category 5e specifications as described in Addendum 5 to the TIA 568 A standard ANSI TIA EIA 568 A 5 Because of the increased speed provided by 1000Base T Gigabit T the network cable quality is more important for proper operation than for either 10Base T or 100Base T Site cablin...

Страница 105: ...25 mm core cladding diameter graded LC Gigabit LH 70 kilometers index 1550 nm low metal content single mini GBIC mode fiber optic cables complying with the ITU T G 652 and ISO IEC 793 2 Type B1 standards Note Between the transmit and receive ends of the cable at least 5db of attenuation is required for a reliable connection This is equivalent to 20Km of the fiber optic cable For distances less tha...

Страница 106: ...ometers 10 GbE ER 9 125 μm core cladding diameter 1550 nm low metal content single mode fiber optic cables complying with the ITU T G 652 and ISO IEC 793 2 Type B1 standards SC single mode cable 2 30 kilometers 40 kilometers on an engineered fiber optic link that meets standards in the specification OMC CX4 Fiber 12 fiber 50 125 μm core cladding diameter multimode Fiber ribbon cable 12 fiber 62 5 ...

Страница 107: ...ater in this appendix for a listing of the signals used on each pin For 1000Base T connections all four pairs of wires in the cable must be available for data transmission See Note on 1000Base T Cable Require ments on page B 2 for more information on 1000Base T cabling For 10 Mbps connections to the ports you can use Category 3 4 or 5 100 ohm differential unshielded twisted pair UTP or shielded tw...

Страница 108: ... 100 Mbps network connections only Cable Diagram Management Module Management Console RJ45 Connector RJ45 Connector Not e Pins 1 and 2 on the management module connector must be wired as a twisted pair to pins 1 and 2 on the management console connector Pins 3 and 6 on the management module connector must be wired as a twisted pair to pins 3 and 6 on the management console connector Pins 4 5 7 and...

Страница 109: ...e brown Not e Pins 1 and 2 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B Pins 4 and 5 on connector A must be wired as a twisted pair to pins 4 and 5 on connector B Pins 7 and 8 on connector A must be wired as a twisted pair to pins 7 and 8 on connector B Pin Assignments For 10...

Страница 110: ...o connect a console to the switch RJ 45 to DB 9 Adapter Pin outs The following illustration shows the internal wiring of the pin connections for the RJ 45 to DB 9 adapter Female RJ 45 Female DB 9 RJ 45 to DB 9 Adapter The following table describes the RJ 45 to DB 9 adapter pin out connections RJ 45 Pin DB 9 Pin Signal Description 1 NC CTS Clear to Send 2 NC DSR Data Set Ready 3 2 TXD Transmit Data...

Страница 111: ...s input wiring terminals power cable or supplied power cable set Whenever it is likely that the protection has been impaired disconnect the power cable until the ground has been restored For LAN cable grounding If your LAN covers an area served by more than one power distribu tion system be sure their safety grounds are securely interconnected LAN cables may occasionally be subject to hazardous tr...

Страница 112: ... sur le cordon d alimentation ou le cordon de raccordement fourni avec le produit Lorsque cette protection semble avoir été endommagée débrancher le cordon d alimentation jusqu à ce que la mise à la terre ait été réparée Mise à la terre du câble de réseau local si votre réseau local s étend sur une zone desservie par plus d un système de distribution de puissance assurez vous que les prises de ter...

Страница 113: ...ts erfordert eine ununterbrochene Sicherheitserdung von der Hauptstromquelle zu den Geräteingabeterminals den Netzkabeln oder dem mit Strom belieferten Netzkabelsatz voraus Sobald Grund zur Annahme besteht daß der Schutz beeinträchtigt worden ist das Netzkabel aus der Wandsteckdose herausz iehen bis die Erdung wiederhergestellt ist Für LAN Kabelerdung Wenn Ihr LAN ein Gebiet umfaßt das von mehr al...

Страница 114: ...d alimentazione oppure al set cavo d alimentazione fornito con il prodotto Ogniqualvolta vi sia probabilità di danneggiamento della protezione disinserite il cavo d alimentazione fino a quando il collegaento a terra non sia stato ripristinato Per la messa a terra dei cavi LAN se la vostra LAN copre un area servita da più di un sistema di distribuzione elettrica accertatevi chei collegamenti a terr...

Страница 115: ...de entrada del aparato el cable de alimentación o el juego de cable de alimentación suministrado Si existe la probabilidad de que la protección a tierra haya sufrido desperfectos desenchufar el cable de alimentación hasta haberse subsanado el problema Puesta a tierra del cable de la red local LAN Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una red de distribución de elect...

Страница 116: ...Safety Information Japan Safety Information Japan J a p a n P o w e r C o r d S t a t e m e n t Please use the attached power cable The attached power cable is not to be used with any other products Safety and Regulatory Statements C 6 ...

Страница 117: ...Safety and Regulatory Statements Safety Information China Safety Information China Safety and Regulatory Statements C 7 ...

Страница 118: ...ent This equipment gener ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense Canada This product complies with Class A Canad...

Страница 119: ...ulatory identification purposes ProCurve 8100fl switches are assigned a Regulatory Model Number The Regulatory Model Number for these switches is RSVLC 0406 This regulatory number should not be confused with the marketing name ProCurve Switch 8100fl or product numbers J8727A J8728A C 9 Safety and Regulatory Statements ...

Страница 120: ...0950 3rd 1999 EN 60825 1 IEC 60825 1 Class 1 Laser EMC EN 55022 1998 A2 2003 CISPR 22 1997 A2 2002 Class A EN55024 A1 2001 A2 2003 CISPR 24 1997 A1 A2 EN 61000 3 2 2000 IEC 61000 3 2 2000 Harmonics EN 61000 3 3 A1 2001 IEC 61000 3 3 1994 Flicker Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and ...

Страница 121: ...亢 亢 Ⲭ X 0 0 0 0 0 䗖䜡 ᅝ㺙ᬃᶊ ᅗ䰘 0 0 0 0 0 0 ӊ 0 0 0 0 0 0 CF व 2 㸼 ℸ䚼ӊՓ ⱘ᠔ ৠ ᴤ Ёℸ ᆇ 䋼ⱘ 䞣ഛԢѢ SJ T11363 2006 㾘ᅮⱘ䰤ࠊ㽕 DŽ X 㸼 ℸ䚼ӊՓ ⱘ㟇ᇥϔ ৠ ᴤ Ёˈℸ ᆇ 䋼ⱘ 䞣催Ѣ SJ T11363 2006 㾘ᅮⱘ䰤ࠊ㽕 DŽ ᠔ᓩ ⱘ ֱՓ ᳳ䰤 䆄ḍ ѻકⱘℷᐌ Փ ᴵӊ བ ᑺ ᑺ ᅮDŽ 䰸䴲 ᯢˈℸ ᄤֵᙃѻક ᶧ ࠊ 䆄䗖 Ѣ᠔ ProCurve Networking by HP ѻકDŽ This information is required by the People s Republic of China as per their legislation titled Management Methods for Controlling Pollution by El...

Страница 122: ... This page is intentionally unused ...

Страница 123: ...my zabývající se sběrem a svozem odpadu nebo v obchodě kde jste produkt zakoupili Bortskaffelse af affald fra husstande i den Europæiske Union Hvis produktet eller dets emballage er forsynet med dette symbol angiver det at produktet ikke må bortskaffes med andet almindeligt husholdningsaffald I stedet er det dit ansvar at bortskaffe kasseret udstyr ved at aflevere det på den kommunale genbrugsstat...

Страница 124: ...n Die getrennte Sammlung und ordnungs gemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert eine Wiederverwertung die die Gesundheit des Menschen und die Umwelt schützt Informationen dazu wo Sie Rücknahmestellen für Ihre Altgeräte finden erhalten Sie bei Ihrer Stadtverwaltung den örtlichen Müllentsorgungsbetrieben oder im Geschäft in dem Sie das Gerät ...

Страница 125: ...alią surinkimo vietą elektros ir elektroninės įrangos atliekoms perdirbti Atskirai surenkamos ir perdirbamos šalintinos įrangos atliekos padės saugoti gamtinius išteklius ir užtikrinti kad jos bus perdirbtos tokiu būdu kuris nekenkia žmonių sveikatai ir aplinkai Jeigu norite sužinoti daugiau apie tai kur galima pristatyti perdirbtinas įrangos atliekas kreipkitės į savo seniūniją namų ūkio atliekų ...

Страница 126: ...nje in recikliranje odslužene opreme prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv način Za podrobnejše informacije o tem kam lahko odpeljete odsluženo opremo na recikliranje se obrnite na pristojni organ komunalno službo ali trgovino kjer ste izdelek kupili Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuario...

Страница 127: ... connecting network devices 2 31 copper B 4 fiber optic B 3 length limitations 2 7 mini GBICs connections 2 7 multimode fiber ribbon B 4 required for different interfaces 2 7 serial cable for console connection 2 28 testing twisted pair cables 5 6 troubleshooting 5 1 twisted pair pin outs B 6 twisted pair requirements B 2 types of fiber optic supported B 1 types of twisted pair supported B 1 wirin...

Страница 128: ...abric modules hot swapping 1 14 installation 2 18 LEDs 1 7 redundancy 1 4 1 14 4 4 removing from chassis 4 6 replacing 4 4 4 7 shutting down with redundancy 4 5 slots 1 4 fail over protection 4 5 fans fan trays described 1 6 installation 2 15 LEDs 1 2 replacing fan trays 4 3 troubleshooting 5 3 fiber optic cables described B 1 requirements B 3 flash memory slot in management module 1 6 G grounding...

Страница 129: ...ng chassis 5 4 verifying module installation 4 7 link aggregation 1 15 link test 5 7 M management module assigning an IP address 3 2 management modules described 1 4 hot swapping 1 14 installation 2 20 LEDs 1 6 PCMCIA card 1 6 redundancy 1 4 1 14 4 4 4 5 removing from chassis 4 6 replacing 4 4 4 7 shutting down with redundancy 4 5 slots 1 4 troubleshooting 5 3 twisted pair cables B 1 managing the ...

Страница 130: ...ts 2 5 Q Quality of Service QoS WRED 1 15 R rack mount kit 2 2 rack mounting precautions 2 5 recycle statements D 1 redundancy 1 14 4 4 fabric modules 1 4 management modules 1 4 Remote Authentication Dial In User Service RADIUS 1 14 replacing hardware compact flash card 4 8 fans 4 3 mini GBICs 4 12 modules 4 4 power supply 4 2 resetting default configuration 5 8 RIP support 1 15 RJ 45 console port...

Страница 131: ...effect 5 5 configuration changes not reinstated after a reboot 5 5 console switch connection 5 4 contact person configuring 3 5 diagnostic tests 5 6 DNS names 5 5 downloading software 5 10 fabric module LEDs 1 7 fans 5 3 interface module 1 8 interface modules 5 3 invalid network topology 5 1 LEDs 5 3 5 4 link test 5 7 lost password 3 8 5 5 management module LEDs 1 6 management modules 5 3 Module S...

Страница 132: ...ndex V VRRP support 1 14 VRRP supported 2 32 VT 100 terminal serial cable connection 2 28 W waste electrical and electronic equipment WEEE statements D 1 weighted random early detection WRED 1 15 6 Index ...

Страница 133: ......

Страница 134: ...ice Copyright 2005 2007 Hewlett Packard Development Company L P Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Printed in Singapore February 2007 Manual Part Number 5991 6191 5991 6191 ...

Отзывы: