background image

4-8

Troubleshooting

Proactive Networking

Troub

lesh

ooti

n

g

Proactive Networking

The ProCurve Series 3400cl Switch devices have built-in management capa-
bilities that proactively help you manage your network including:

finding and helping you fix the most common network error conditions 
(for example, faulty network cabling, and non-standard network topolo-
gies)

informing you of the problem with clear, easy-to-understand messages

recommending network configuration changes to enhance the perfor-
mance of your network

The following interfaces provide tests, indicators, and an event log that can 
be used to monitor the switch and its network connections and to help you 
take advantage of these proactive networking features:

ProCurve Manager - an SNMP-based network management tool that is 
included with your switch.

A graphical web browser interface that you can use to manage your switch 
from a PC running a supported web browser, for example Microsoft 
Internet Explorer, and Netscape Communicator.

A full-featured easy-to-use console interface that you can access by 
connecting a standard terminal or PC running a terminal emulator to the 
switch’s console port. The cable to make that connection is provided with 
your switch. The console interface is also accessible through a Telnet 
connection.

For more information on using these software tools to diagnose and manage 
your switch, see the “Troubleshooting” chapter in the 

Management and 

Configuration Guide

, which is on the Documentation CD-ROM that came 

with your switch.

Содержание ProCurve 3400cl-24G

Страница 1: ...Installation and Getting Started Guide www procurve com ProCurve Series 3400cl Switches ...

Страница 2: ......

Страница 3: ...ProCurve Series 3400cl Switch Installation and Getting Started Guide ...

Страница 4: ...emark of Sun Microsystems Inc Disclaimer HEWLETT PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this ...

Страница 5: ... Switch Included Parts 2 1 Installation Procedures 2 3 Summary 2 3 Installation Precautions 2 4 1 Prepare the Installation Site 2 5 2 Optional Install or Remove a cl Module 2 7 3 Optional Install or Remove a Transceiver 2 8 4 Optional Install or Remove mini GBICs 2 9 5 Verify the Switch Passes Self Test 2 11 LED Behavior 2 12 6 Mount the Switch 2 13 Rack or Cabinet Mounting 2 13 Rack Mounting the ...

Страница 6: ...t Topology 2 31 3 Getting Started With Switch Configuration Recommended Minimal Configuration 3 1 Using the Console Setup Screen 3 2 Where to Go From Here 3 4 To Recover from a Lost Manager Password 3 4 Using the IP Address for Remote Switch Management 3 5 Starting a Telnet Session 3 5 Starting a Web Browser Session 3 5 4 Troubleshooting Basic Troubleshooting Tips 4 1 Diagnosing with the LEDs 4 4 ...

Страница 7: ... B 1 Mode Conditioning Patch Cord for Gigabit LX B 3 Installing the Patch Cord B 4 Recommended Patch Cords B 4 Twisted Pair Cable Connector Pin Outs B 5 Auto MDIX Feature B 5 Using Fixed Configurations B 5 Other Wiring Rules B 5 Straight Through Twisted Pair Cable for 10 Mbps or 100 Mbps Network Connections B 7 Cable Diagram B 7 Pin Assignments B 7 Crossover Twisted Pair Cable for 10 Mbps or 100 M...

Страница 8: ...razioni sulla sicurezza C 4 Consideraciones sobre seguridad C 5 Safety Information Japan C 6 Safety Information China C 7 EMC Regulatory Statements C 8 U S A C 8 Canada C 8 Australia New Zealand C 8 Japan C 8 Korea C 9 Taiwan C 9 European Community C 10 D Recycle Statements Waste Electrical and Electronic Equipment WEEE Statements D 1 Index ...

Страница 9: ...ng 10 100 1000Base T RJ 45 ports four dual personality ports either auto sensing 10 100 1000Base T RJ 45 or mini GBIC and one slot is provided in the back of the device to support a two port 10 Gigabit per second Ethernet 10 GbE module to provide box connectivity to other switch boxes to a 10 Gigabit per second concentrator or to any Ethernet compatible uplink The Series 3400cl Switch devices can ...

Страница 10: ...computers printers and servers to provide dedicated bandwidth to those devices and can build a switched network infrastructure by connecting the switch to hubs other switches or routers In addition the Series 3400cl Switch devices offer full network management capabilities This chapter describes the Series 3400cl Switch devices including Front and back of the switches Switch features ...

Страница 11: ... Dual personality ports 1000Base T or mini GBIC Console port Auxiliary port Auxiliary port LED On the 3400cl 48Gswitch the consoleand Auxiliary portsarelocated on the backof the unit ProCurve Switch 3400cl 48G Power and Fault LEDs Test Fan RPS and Module Status LEDs Switch port LEDs Reset and Clear buttons Port LED Mode select button and indicator LEDs 10 100 1000 T RJ 45 ports Dual personality po...

Страница 12: ...ns you can use either straight through or crossover twisted pair cables to connect any network device to the switch Dual Personality Port Operation By default the RJ 45 connectors are enabled Ifamini GBICisinstalledinaslot itisenabledandtheassociated RJ 45 connector is disabled and cannot be used If the mini GBIC is removed the associated RJ 45 port is automatically re enabled One 10 gigabit expan...

Страница 13: ... blink simultaneously Port LEDs green over laid with the port number Displays port link information network activity information whether the port is configured for full duplex operation or the speed of the connection depending on the Port LED View selected See Port LED View Select Button and Indicator LEDs on the next page for more information If a fault has occurred on the port the port LED will ...

Страница 14: ... green On Off Port is in use Port is not in use The blinking behavior is an on off cycle once every 1 6 seconds approximately Switch LEDs State Meaning RPS modes This table describes the behavior of the RPS LED associated with the 600 RPS EPS operation Power RPS EPS Fault Power LED RPS LED Fault LED Description On Off Off Normal operation The 600 RPS EPS is not connected or not powered On On Off N...

Страница 15: ...ngle LED for each port The operation of this LED is controlled by the LED Mode select button and the current setting is indicated by the LED Mode indicator LEDs near the button Press the button to step from one view mode to the next Port LED one for each port LED Mode select button and indicator LEDs Expansion Module LED ProCurve Switch 3400cl 24G Port LED one for each port LED Mode select button ...

Страница 16: ...oweredon Thisactionclears any temporary error conditions that may have occurred and executes the switch self test Clear Button This button is used for these purposes Deleting Passwords When pressed by itself for at least one second the button deletes any switch console access passwords that you may have configured Use this feature if you have misplaced the password and need console access This but...

Страница 17: ...ff On Expansion module is plugged into expansion slot and operating correctly Expansion module s power has been turned OFF and the card can be removed from the box if necessary Expansion module is plugged into expansion slot but has experienced a fault Expansion Module LEDs per port Link Green On Off Blinking Indicates that the port LEDs are displaying link information if the port LED is on the po...

Страница 18: ...e back of the 3400cl 48G Power Connector The Series 3400cl Switch devices do not have a power switch they are powered on when connected to an active AC power source These switches automatically adjust to any voltage between 100 127 and 200 240 volts and either 50 or 60 Hz There are no voltage range settings required AC power connector Cooling vents make sure this is not obstructed for proper switc...

Страница 19: ...r ports meaning that all connections can be made using straight through twisted pair cables Cross over cables are not required although they will also work The pin operation of each port is automatically adjusted for the attached device if the switch detects that another switch or hub is connected to the port it configures the port as MDI if the switch detects that an end node device is connected ...

Страница 20: ...liant VLANs so you can divide the attached end nodes into logical groupings that fit your business needs support for many advanced features to enhance network performance for a description see the Management and Configuration Guide which is on the Documentation CD ROM that is included with your switch download of new switch software for product enhancements or bug fixes ...

Страница 21: ...ocumentation CD ROM contains PDF file copies of the documentation for the Series 3400cl Switch devices including the Management and Configuration Guide and for most other ProCurve switches ProCurve Manager CD ROM and booklet Read Me First Customer Support Warranty booklet Console cable Accessory kits 5064 2085 for Switch 3400cl 24G 5069 5705 for Switch 3400cl 48G two mounting brackets two mounting...

Страница 22: ...n i n g Please use the power cord supplied with your product This power cord is not to be used with other products Australia New Zealand China Continental Europe Denmark Japan Switzerland United Kingdom Hong Kong Singapore United States Canada Mexico 8120 6803 8120 8377 8120 6802 8120 6806 8120 6804 8120 6807 8120 8709 8120 6805 ...

Страница 23: ... correct switch operation When self test is complete unplug the switch 6 Mount the switch page 2 13 The Switch can be mounted in a 19 inch telco rack in an equipment cabinet or on a horizontal surface 7 Connect power to the switch page 2 19 Once the switch is mounted plug it into the nearby main power source 8 Connect the network cables page 2 20 Using the appropriate network cables connect the ne...

Страница 24: ... displaying the mark of the safety agency that defines the regulations for power cords in your country The mark is your assurance that the power cord can be used safely with the switch When installing the switch the AC outlet should be near the switch and should be easily accessible in case the switch must be powered off Ensure the switch does not overload the power circuits wiring and over curren...

Страница 25: ... Pair Cables 10 100 1000Base T For either 10 100 Mbps or 1000 Mbps operation Category 5 or better 100 ohm UTP or shielded twisted pair STP balanced cable For 1000 Mbps gigabit operation Category 5e cabling or better is recommended 100 meters Note The Series 3400cl Switch devices are compatible with the IEEE 802 3ab standard including the Auto MDI MDI X feature which allows use of either straight t...

Страница 26: ...d with LC connectors The cables must comply with the ITU T G 651 and ISO IEC 793 2 Type A1b or A1a standards 62 5 µm cable 160 MHz km 220 meters 200 MHz km 275 meters 50 µm cable 400 MHz km 500 meters 500 MHz km 550 meters Gigabit LX on Gigabit LX LC mini GBIC Single mode fiber optic cables designed for Gigabit Ethernet 9 125 µm core cladding diameter 1310 nm low metal content cables fitted with L...

Страница 27: ... a module during scheduled downtime with the switch powered off 1 Remove the cover plate 2 Insert the module aligning with the guides in the slot 3 Once the contacts have engaged use the extractor handles to seat the module completely 4 Tighten the captive screws Refer to the cl Module Installation Guide for more details If you have installed a media flex module you can now install a transceiver S...

Страница 28: ...s b Push firmly until the gasket seats against the bulkhead Not e When switch power is on the Link and Activity LEDs will come on for approximately two seconds and then go off This is confirmation the trans ceiver is completely seated c If your transceiver has a bail move the bail up if not your transceiver is now completely installed Refer to the ProCurve Switch cl Modules Installation Guide for ...

Страница 29: ... GBIC When this manual was printed the supported mini GBICs include the following ProCurve Gigabit SX LC mini GBIC J4858B ProCurve Gigabit LX LC mini GBIC J4859B ProCurve Gigabit LH LC mini GBIC J4860B C a u t i o n Use only supported genuine ProCurve mini GBICs with your switch Non ProCurve mini GBICs are not supported and their use may result in product malfunction Should you require additional ...

Страница 30: ...hanisms a plastic tab on the bottom of the mini GBIC a plastic collar around the mini GBIC or a wire bail To remove the mini GBICs that have the plastic tab or plastic collar push the tab or collar toward the switch until you see the mini GBIC release from the switch you can see it move outward slightly and then pull it from the slot To remove the mini GBICs that have the wire bail lower the bail ...

Страница 31: ... do not have a power switch They are powered on when the power cord is connected to the switch and to a power source For safety the power outlet should be located near the switch installation The switch automatically adjusts to any voltage between 100 240 volts and either 50 or 60 Hz No voltage range settings are required If your installation requires a different power cord than the one supplied w...

Страница 32: ...onds to complete LED Behavior During the self test Initially all the status LED Mode and port LEDs are on for most of the duration of the test Most of the LEDs go off and then may come on again during phases of the self test For the duration of the self test the Test LED stays on ProCurve Switch 3400cl 24G Power and Fault LEDs Switch port LEDs Test LED Switch port LEDs Power and Fault LEDs ProCurv...

Страница 33: ...lp 6 Mount the Switch After the switch passes self test you are ready to mount the switch in a stable location The Series 3400cl Switch devices can be mounted in these ways in a rack or cabinet on a horizontal surface Rack or Cabinet Mounting The Series 3400cl Switch devices are designed to be mounted in any EIA standard 19 inch telco rack or communication equipment cabinet WARN I NG For safe oper...

Страница 34: ...he mounting brackets to the switch with the included 8 mm M4 screws Not e The mounting brackets have multiple mounting holes and can be rotated allowing for a wide variety of mounting options These include mounting the switch so its front face is flush with the face of the rack or mounting it in a more balanced position as shown in the illustration 8 mm M4 screws ...

Страница 35: ...ocedures Installing the Switch 2 Hold the switch with attached brackets up to the rack and move it vertically until rack holes line up with the bracket holes then insert and tighten the four number 12 24 screws holding the brackets to the rack ...

Страница 36: ...hese include mounting the switch so its front face is flush with the face of the rack or mounting it in a more balanced position as shown in the illustration Steps 2 3 and 4 on the following pages describe a convenient method of mounting the switch in a rack by placing it on two screws that you first install in the rack You may instead just hold the switch with attached brackets up to the rack and...

Страница 37: ...inet upright as shown in the illustration below Ensure that the screws are at the same level in each upright 3 Place the switch in the rack and lower it so the notches in the bottom of the bracket slide onto the screws then tighten these screws Partiallyinstallascrew into the top hole of a close 0 5 inch pair on both sides of the rack Lowerswitchwithmounting brackets onto the partially installed s...

Страница 38: ...2 18 Installing the Switch Installation Procedures Installing the Switch 4 Install the other number 12 24 screw into the upper hole in each bracket Tighten these screws ...

Страница 39: ...switch within the embossed angled lines Use a sturdy surface in an uncluttered area You may want to secure the networking cables and switch power cord to the table leg or other part of the surface structure to help prevent tripping over the cords C a u t i o n Make sure the air flow is not restricted around the sides and back of the switch 7 Connect the Switch to a Power Source 1 Plug the included...

Страница 40: ...g and pull the plug out of the jack Connecting Cables to mini GBICs Not e Each of the four mini GBIC slots is shared with the associated 10 100 1000Base T RJ 45 port If a mini GBIC is installed in a slot the associated RJ 45 port is disabled If you have any mini GBICs installed in the switch the type of network connections you will need to use depends on the type of mini GBICs you have installed S...

Страница 41: ...redundant 12V power to a connected switch but only one connector can provide this power at a given time If a switch with no AC power is connected to an operating RPS EPS it will NOT immediately power up this new switch Power can only be provided to a switch if it is first powered on and operating correctly Then when the power to the switch fails power will be provided from the RPS EPS if it is ava...

Страница 42: ...e Connected Power Status Message Off Off Off Nothing Connected On or Off Off On Not a valid state should never happen Off On Off Switch is connected RPS is available but not required Off On On RPS is powering the connected device Blinking Off Blinking RPS port is in fault mode Off On Blinking Switch is requesting power RPS can not provide it Blinking On Off Switch is unplugged but RPS is powering ...

Страница 43: ...RPS EPS cable without causing a reboot of the switch or causing the power supply in either the RPS EPS or switch to shut down temporarily or permanently For more information refer to the documentation that came with the RPS EPS Device Connected Power Status R1 R2 R3 R4 R5 R6 E1 Device Connected Power Status E2 RPS 1 RPS 2 RPS 3 RPS 4 RPS 5 RPS 6 EPS 1 EPS 2 EPS Power 50V 370W total for PoE applica...

Страница 44: ...ork and a VT 100 terminal emulator This method requires that you first configure the switch with an IP address and subnet mask by using either out of band console access or through DHCP Bootp For more information on IP addressing and on starting a Telnet session see chapter 3 Getting Started With Switch Configuration and the Man agement and Configuration Guide which is on the Documentation CD ROM ...

Страница 45: ...pter at one end of the console cable 2 Turn on the terminal or PC s power and if using a PC start the PC terminal program 3 Press Enter two or three times and you will see the copyright page and the message Press any key to continue Press a key and you will then see the switch console command CLI prompt for example ProCurve Switch 3400cl 48G If you want to continue with console management of the s...

Страница 46: ...h is designed to be used primarily as a desktop switch to which end nodes printers and other peripherals and servers are directly connected as shown in the above illustration Notice that the end node devices are connected to the switch by straight through or crossover twisted pair cables Either cable type can be used because of the IEEE Auto MDI MDI X features on the Switch Server with Gigabit Eth...

Страница 47: ...re both connected to a Switch The devices attached to the two hubs can now communicate with each other through the switch They can also all communicate with the server that is connected to a 1000Base T port on the switch hp procur ve s witch 2650 P ower Fault J4899A Act FDx Max hp pr ocur ve s witch 2650 P ower Fault J4899A Act F Dx Max PCs local servers and peripherals PCs local servers and perip...

Страница 48: ...d pair cable Category 3 or 4 cable can also be used if the connection is 10 Mbps only In all cases the device ports must be configured to auto negotiate the link characteristics for this feature to work The switch in turn can be connected to a network backbone through fiber optic cabling connected to a Gigabit SX LX or LH mini GBIC installed in the switch Now all the devices on these network segme...

Страница 49: ...Dx Max Power F ault switch 5304xl J4850A Console procurve hp Reset Clear S elf T est U se x l modules only L ED Mode S elect Act FDx Max S tatus Power Modules F an 1 2 B C D E F G A H A C D B module xl J4878A Link Mode 1 2 3 4 1 2 3 4 module x l J4878A Link Mode 1 2 3 4 1 2 3 4 module x l J4878A Link Mode 1 2 3 4 1 2 3 4 S erver with Gigabit E thernet NIC S erver with Gigabit E thernet NIC Gigabit...

Страница 50: ...6 switches can be connected together in such a virtual stack Youidentifytheswitchasthe Commander andgivethatswitchanIPaddress Up to 15 other switches in the network can then easily be configured as Members of the stack and managed through the Commander s IP address The management includes Telnet access and web browser interface access to the Commander and to each Member switch through the Commande...

Страница 51: ... F H module x l J4878A Link Mode 1 2 3 4 1 2 3 4 module x l J4878A Link Mode 1 2 3 4 1 2 3 4 J4821A module xl 1 1 Link Mode 2 2 3 3 4 4 100 1000B ase T P orts J4821A module x l 1 1 Link Mode 2 2 3 3 4 4 100 1000Base T P orts J4821A module xl 1 1 Link Mode 2 2 3 3 4 4 100 1000Base T Ports J4821A module xl 1 1 Link Mode 2 2 3 3 4 4 100 1000B ase T P orts R P S J4820A 1 7 6 12 2 8 3 9 4 10 5 11 1 7 1...

Страница 52: ... This page is intentionally unused ...

Страница 53: ... and subnet mask compatible with your network Also you should configure a Manager password to control access privileges from the console and web browser interface Other parameters in the Switch Setup screen can be left at their default settings or you can configure them with values you enter Many other features can be configured through the switch s console interface to optimize the switch s perfo...

Страница 54: ... the switch for manage ment and password protection in your network is to use a direct console connection to the switch start a console session and access the Switch Setup screen 1 Using the method described in the preceding section connect a terminal device to the switch and display the switch console command CLI prompt the default display The CLI prompt appears displaying the switch model number...

Страница 55: ... West or East of GMT Community Name public Default setting recommended Spanning Tree Enabled No Default setting recommended unless STP is already running on your network or the switch will be used in complex network topologies Default Gateway blank Optional Enter the IPaddressofthenext hopgateway node ifnetwork traffic needs to be able to reach off subnet destinations Time Sync Method None Optiona...

Страница 56: ...nager Some basic information on managing your switch is included in the next section For more information on the console web browser and SNMP management interfaces and all the features that can be configured on the Switch 3400 please see the Management and Configuration Guide which is on the Documentation CD ROM that came with your switch To Recover from a Lost Manager Password If you cannot start...

Страница 57: ... a PC that is on the same subnet as the switch and connect to the switch s IP address 3 You will see the copyright page and the message Press any key to continue Press a key and you will then see the switch console command CLI prompt for example ProCurve Switch 3400 24G Enter help or to see a list of commands that can be executed at the prompt Entering any command followed by help provides more de...

Страница 58: ... interface please see the Management and Configuration Guide which is on the Documentation CD ROM that came with your switch An extensive help system is also available for the web browser interface To access the help system though the subnet on which the switch is installed must have access to the internet or ProCurve Manager needs to be installed on a network management station that is on the sub...

Страница 59: ...rdware diagnostic tests page 4 9 restoring the factory default configuration page 4 11 downloading new software to the Switch 3400 page 4 12 HP Customer Support Services page 4 13 Basic Troubleshooting Tips Most problems are caused by the following situations Check for these items first when starting your troubleshooting Connecting to devices that have a fixed full duplex configuration The RJ 45 p...

Страница 60: ...ogy Common topology faults include excessive cablelengthandexcessiverepeaterdelaysbetweenendnodes Ifyouhave network problems after recent changes to the network change back to the previous topology If you no longer experience the problems the new topology is probably at fault Sample topologies are shown at the end of chapter 2 in this book and some topology configuration guidelines can be found on...

Страница 61: ...s disabled through software Use the switch console to determine the port s configuration and verify that there is not an improper or undesired configuration of any of the switch features that may be affecting the port For more information see the Management and Configuration Guide which is on the Documenta tion CD ROM that came with your switch For more information on possible network problems and...

Страница 62: ...s Power Fault Module Mdl Status Fault RPS Status Test Fan Status Port LED in Link view mode Off with powercord plugged in On Prolonged On Prolonged On On Blinking Blinking On Blinking Off Blinking On Blinking See tip 5 Blinking Blinking On Off Off Off with cable connected On Off Off On but the port is not communicating On Blinking On On Blinking F1 Blinking B2 Blinking Blinking This LED is not imp...

Страница 63: ... console Main Menu If necessary to resolve the problem contact your HP authorized LAN dealer or use the electronic support services from HP to get assistance See the Customer Support Warranty booklet for more information Oneorbothofthe switch cooling fans may have failed Try disconnecting power from the switch and wait a few moments Then reconnect the power to the switch and check the LEDs again I...

Страница 64: ...o the transmit port on the connected device For the dual personality 10 100 1000 T ports be sure a mini GBIC is not installed in the associated slot For 1000Base T connections verify that the network cabling complies with the IEEE 802 3ab standard the cable should be installed according to the ANSI TIA EIA 568 A 5 specifications Cable testing should comply with the stated limitations for Attenu at...

Страница 65: ...ed as disabled Other switch features that may affect the port operation include VLANs and IGMP Use the switch console to see how the port is configured for these features For software troubleshooting tips seethechapter Troubleshooting inthe Management and Configuration Guide which is on the Documentation CD ROM that came with your switch Make sure also the device at the other end of the connection...

Страница 66: ...o help you take advantage of these proactive networking features ProCurve Manager an SNMP based network management tool that is included with your switch A graphicalweb browser interface that you can use to manage your switch from a PC running a supported web browser for example Microsoft Internet Explorer and Netscape Communicator A full featured easy to use console interface that you can access ...

Страница 67: ...ult and Self Test LEDs on the front of the switch go off after approximately 50 seconds If these LEDs stay on longer than 60 seconds or begin blinking there may be a problem with the switch See Diagnosing With the LEDs on page 4 4 for information on interpreting the LED patterns and LED behaviors in chapter one Checking Console Messages Useful diagnostic messages may be displayed on the console sc...

Страница 68: ...IP networks that sends test packets to any device identified by its IP address These tests can be performed through the switch console interface from a terminal connected to the switch or through a Telnet connection or from the switch s web browser interface For more information see the Management and Configuration Guide whichisontheDocumentationCD ROMthatcame with your switch These tests can also...

Страница 69: ...ault settings for a reason other than configuration problems you should save the switch configuration prior to performing the factory default reset Then after the reset and resolution of the original problem you can restore the saved configuration to the switch For both the save and restore processes you can use the console copy command For more information on this command see the Management and C...

Страница 70: ...he switch new software can be downloaded to the switch through several methods for product enhance ments and new features For more information see the Management and Configuration Guide which is on the Documentation CD ROM that came with your switch The new switch software would be available on the ProCurve Web site http www procurve com ...

Страница 71: ...sistance both with services that they offer and with services offered by ProCurve Before Calling Support Before calling your networking dealer or ProCurve Support to make the support process most efficient you first should have retrieved the following information Information Item Information Location product identification including mini GBICs thefront of theswitch ProCurveSwitch 3400 J4905A or J4...

Страница 72: ... This page is intentionally unused ...

Страница 73: ... 43 0 cm 16 9 in Height 4 4 cm 1 7 in 4 4 cm 1 7 in Weight 4 62 kg 10 20 lbs 4 88 kg 10 75 lbs 3400cl 24G J4905A 3400cl 48G J4906A AC voltage 100 127 200 240 volts 100 127 200 240 volts Maximum current 2 0A 1 0A 3 0A 1 5A Frequency range 50 60 Hz 50 60 Hz Operating Non Operating Temperature 0 C to 55 C 32 F to 131 F 40 C to 70 C 40 F to 158 F Relative humidity non condensing 15 to 95 at 40 C 104 F...

Страница 74: ...ards IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX IEEE 802 3 10Base T The1000MbpsLCfiber opticportsontheGigabit SXandGigabit LXmini GBIC transceivers are compatible with the IEEE 802 3z Gigabit SX and Gigabit LX standards Safety Complies with EN60950 IEC 950 CSA 22 2 No 950 UL 1950 Lasers The Gigabit SX LC mini GBIC and the Gigabit LX LC mini GBIC both of which can be installed in the Switch 340...

Страница 75: ...Base T Cable Requirements The Category 5 networking cables that work for 100Base TX connections should also work for 1000Base T as long as all four pairs are connected But for the most robust connections you should use cabling that complies with the Category 5e specifications as described in Addendum 5 to the TIA 568 A standard ANSI TIA EIA 568 A 5 10 Mbps Operation Category 3 4 or 5 100 ohm unshi...

Страница 76: ...ng cable and they must also comply with the cabling standards Fiber Optic 1000Base SX 62 5 125 µm or 50 125 µm core cladding diameter graded index multimode fiber optic cables complying with the ITU T G 651 and ISO IEC 793 2 Type A1b or A1a respec tively fitted with LC connectors 1000Base LX single mode fiber optic cables complying with the ITU T G 652 and ISO IEC 793 2 Type B1 standards fitted wi...

Страница 77: ...e runs an external Mode Conditioning Patch Cord may need to be installed between the Gigabit LX transmitting device and the multimode network cable to provide the transmission conditioning If you experience a high number of transmission errors on the Gigabit LX ports usually CRC or FCS errors you may need to install one of these patch cords between the Gigabit LX port in your switch and your multi...

Страница 78: ...you purchase a patch cord that has LC connectors on the end that connects to the Gigabit LX mini GBIC and has multimode fibers that match the characteristics of the multimode fiber in your network Recommended Patch Cords Hewlett Packard maintains a list of recommended Mode Conditioning Patch Cords that have been tested and verified to operate correctly with the ProCurve Gigabit LX Transceiver and ...

Страница 79: ... If you happen to use a correctly wired crossover cable though the switch will still be able to automatically detect the MDI MDI X operation and link correctly to the connected device Not e Using Fixed Configurations If the port configuration is changed to any of the fixed configurations though for example 100 Mbps full duplex the port operates as MDI X only and the correct cable type must be used...

Страница 80: ...or Pin Outs Switch Ports and Network Cables For 100 Mbps connections to the ports use 100 ohm Category 5 UTP or STP cable only as supported by the IEEE 802 3u Type 100Base TX stan dard For 1000 Mbps connections 100 ohm Category 5e or better cabling is recommended ...

Страница 81: ...uration for example 100 Mbps Full Duplex the ports operate as MDI X ports and straight through cables must be then used for connections to PC NICs and other MDI ports Cable Diagram Not e Pins 1 and 2 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B Pins 4 5 7 and 8 are not used i...

Страница 82: ... 100 Mbps Full Duplex the ports operate as MDI X ports and crossover cables must be then used for connections to hubs or switches or other MDI X network devices Cable Diagram Not e Pins 1 and 2 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 4 5 7 and 8 are not used in this...

Страница 83: ...e Pins 1 and 2 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B Pins 4 and 5 on connector A must be wired as a twisted pair to pins 4 and 5 on connector B Pins 7 and 8 on connector A must be wired as a twisted pair to pins 7 and 8 on connector B Pin Assignments For 1000Base T ope...

Страница 84: ... This page is intentionally unused ...

Страница 85: ...o hazardous transient volt ages such as lightning or disturbances in the electrical utilities power grid Handle exposed metalcomponents ofthe network with caution Servicing There are no user serviceable parts inside these products Any servicing adjustment maintenance or repair must be performed only by service trained personnel These products do not have a power switch they are powered on when the...

Страница 86: ...soumis à des surtensions transitoires dangereuses telles que la foudre ou des perturba tions dans le réseau d alimentation public Manipulez les composants métalliques du réseau avec précautions Aucune pièce contenue à l intérieur de ce produit ne peut être réparée par l utilisateur Tout dépannage réglage entretien ou réparation devra être confié exclusivement à un personnel qualifié Cet appareil n...

Страница 87: ...nnungen aus gesetzt werden beispielsweise durch Blitz oder Störungen in dem Starkstromnetz des Elektrizitätswerks Bei der Handhabung exponierter Metallbestandteile des Netzwerkes Vorsicht walten lassen Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile Wartungs Anpassungs Instandhaltungs oder Reparaturarbeiten dürfen nur von geschultem Bedienungspersonal durchgeführt werden Die...

Страница 88: ...llegati fra loro i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni transitorie ad esempio provocate da lampi o disturbi nella griglia d alimen tazione della società elettrica siate cauti nel toccare parti esposte in metallo della rete Nessun componente di questo prodotto può essere riparato dall utente Qualsiasi lavoro di riparazione messa a punto manutenzione o assistenza v...

Страница 89: ... seguro Es posible que los cables de la LAN se vean sometidos de vez en cuando a voltajes momentáneos que entrañen peligro rayos o alteraciones en la red de energía eléctrica Manejar con precaución los componentes de metal de la LAN que estén al descubierto Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario Todas las reparaciones ajustes o servicio de mantenimien...

Страница 90: ...C 6 Safety and EMC Regulatory Statements Safety Information Japan Safety and EMC Regulatory Statements Safety Information Japan J a p a n P o w e r C o r d Wa r n i n g ...

Страница 91: ...C 7 Safety and EMC Regulatory Statements Safety Information China Safety and EMC Regulatory Statements Safety Information China ...

Страница 92: ...ment is operated in a commercial environment This equipment gener ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense Canada...

Страница 93: ...C 9 Safety and EMC Regulatory Statements EMC Regulatory Statements Safety and EMC Regulatory Statements Korea Taiwan ...

Страница 94: ...60950 1999 EMC EN 55022 1998 A1 2000 A2 2002 CISPR 22 1997 A1 2000 A2 2002 Class A EN 55024 1998 A1 2001 CISPR 24 1997 A1 2001 A2 2002 EN 61000 3 2 2000 IEC 61000 3 2 2000 A1 2001 EN 61000 3 3 1995 A1 2001 IEC 61000 3 3 2002 Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE markin...

Страница 95: ...er at udstyret genvindes på en måde der beskytter både mennesker og miljø Yderligere oplysninger om hvor du kan aflevere kasseret udstyr til genvinding kan du få hos kommunen den lokale genbrugsstation eller i den butik hvor du købte produktet Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus See tootel või selle pakendil olev sümbol näitab et kõnealust toodet ei tohi koos teiste maj...

Страница 96: ...ben Die getrennte Sammlung und ordnungs gemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert eine Wiederverwertung die die Gesundheit des Menschen und die Umwelt schützt Informationen dazu wo Sie Rücknahmestellen für Ihre Altgeräte finden erhalten Sie bei Ihrer Stadtverwaltung den örtlichen Müllentsorgungsbetrieben oder im Geschäft in dem Sie das Gerä...

Страница 97: ...dzīves atkritumiem Jūs atbildat par to lai nolietotās iekārtas tiktu nodotas speciāli iekārtotos punktos kas paredzēti izmantoto elektrisko un elektronisko iekārtu savākšanai otrreizējai pārstrādei Atsevišķa nolietoto iekārtu savākšana un otrreizējā pārstrāde palīdzēs saglabāt dabas resursus un garantēs ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā lai pasargātu vidi un cilvēku veselību ...

Страница 98: ...ný výrobok sa nesmie likvidovať s domovým odpadom Povinnosťou spotrebiteľa je odovzdať vyradené zariadenie v zbernom mieste ktoré je určené na recykláciu vyradených elektrických a elektronických zariadení Separovaný zber a recyklácia vyradených zariadení prispieva k ochrane prírodných zdrojov a zabezpečuje že recyklácia sa vykonáva spôsobom chrániacim ľudské zdravie a životné prostredie Informácie...

Страница 99: ...band access 2 24 buttons Clear button 1 8 Port LED View select button 1 7 Reset button 1 8 C cabinet mounting the switch in 2 13 cables 1000Base LH connections 2 6 fiber optic cable specifications B 2 1000Base LX connections 2 6 fiber optic cable specifications B 2 1000Base SX connections 2 6 fiber optic cable specifications B 2 1000Base T connections 2 5 connecting cables to switch ports 2 20 eff...

Страница 100: ...sswords 1 8 description back of switch 1 10 front of switch 1 3 LEDs 1 5 switch 1 1 desktop switch sample topology 2 26 DHCP automatic switch configuration 3 2 for in band access 2 24 diagnostic tests 4 9 checking the console messages 4 9 checking the LEDs 4 9 end to end connectivity 4 10 testing the switch only 4 9 testing twisted pair cabling 4 10 downloading new switch software 4 12 dual person...

Страница 101: ...during self test 2 13 showing error conditions 4 4 FDx 1 5 1 8 Link 1 5 1 9 location on switch 1 3 on switch 1 5 port description 1 5 Port LED View select indicators 1 5 Port View selecting the display 1 7 Power 1 5 behavior during self test 2 13 Self Test 1 5 behavior during self test 2 12 T and M 1 6 length limitations 1000Base LH connections 2 6 1000Base LX connections 2 6 1000Base SX connectio...

Страница 102: ...ehavior during self test 2 13 behaviors 1 5 location on switch 1 3 power source connecting the switch to 2 19 precautions mounting the switch 2 4 power requirements 2 4 preparing the installation site 2 5 Proactive Network tools diagnostics with 4 8 R rack mounting precautions 2 4 mounting the switch in 2 13 recycle statements D 1 Redundant Power Supply 2 21 regulatory statements C 8 Reset button ...

Страница 103: ...cking the LEDs 4 9 diagnostic tests 4 9 end to end communications 4 10 link test 4 10 Ping test 4 10 switch operation 4 9 switch to device communications 4 10 twisted pair cabling 4 10 tips for troubleshooting 4 1 topologies effects of improper topology 4 2 samples of 2 26 transceiver install or remove 2 8 troubleshooting 4 1 basic tips 4 1 checking port configuration 4 3 checking the console mess...

Страница 104: ...6 Index Index V VT 100 terminal serial cable connection for 2 25 W wiring rules for twisted pair cables B 5 ...

Страница 105: ... This page is intentionally unused ...

Страница 106: ... This page is intentionally unused ...

Страница 107: ......

Страница 108: ...t notice Copyright 2004 2006 Hewlett Packard Development Company L P Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Printed in Singapore March 2006 Manual Part Number 5991 4702 5991 4702 ...