3-14
Troubleshooting and Diagnostics
HP OmniBook 7100
0182h
Make sure that another application is not using
all extended memory allocated by
HIMEM.SYS.
0183h
No extended memory. Check installation of
RAM boards. Replace the motherboard.
0190h -
01A0h
For 01FFFFFFh and below, replace the
motherboard. For 02000000h and above,
replace the corresponding RAM board (each
01000000h represents 16MB).
Hard Disk Tests
0201h
Replace the hard disk. Replace the
motherboard.
0202h -
0204h
Rerun the test. If error persists, replace the
hard disk.
0205h
Replace the motherboard.
0207h
Run BIOS Setup and check the hard disk type.
Check internal and external hard disk
connectors and motherboard connector.
Replace the hard disk.
0208h -
0209h
Transient DMA error. Rerun the test.
020Ah -
0211h
Rerun the test. Run SCANDISK or equivalent.
0220h
Replace the motherboard.
0240h
Replace the hard disk. Replace the
motherboard.
0280h
Check internal and external hard disk
connectors and motherboard connector.
Replace the hard disk.
0281h
Replace the hard disk.
02AAh
Check internal and external hard disk
connectors and motherboard connector.
Replace the hard disk.
02CCh
Run BIOS Setup and check the hard disk type.
Replace the hard disk or the motherboard.
02EEh
For the performance test, run BIOS Setup and
temporarily select a drive type that has more
than 200 cylinders.
02F1h
Recreate the Hibernate partition, then run
FDISK to partition the hard disk.
02F2h
Run FDISK to make one partition active. If
necessary, recreate the Hibernate partition,
then run FDISK to partition the hard disk.
02F3h
Run FDISK to check for overlapping partitions.
If necessary, recreate the Hibernate partition,
then run FDISK to partition the hard disk.
02F4h
Check for the presence of a boot sector virus.
If necessary, recreate the Hibernate partition,
then run FDISK to partition the hard disk.
02F5h
Reformat the partition.
02F6h
Recreate the Hibernate partition, then run
FDISK to partition the hard disk.
02FFh
Check internal and external hard disk
connectors and motherboard connector.
Replace the hard disk. Replace the
motherboard.
Floppy Disk Tests
0301h
Replace the floppy drive. Replace the
motherboard.
0302h
Run BIOS Setup and check the floppy drive
type. Replace the floppy drive.
0303h
Insert a floppy disk without write protection.
0304h
Run BIOS Setup and check the floppy drive
type. Replace the floppy drive.
0305h
Replace the motherboard.
0307h
Run BIOS Setup and check the floppy drive
type. Check the connectors on the floppy drive
and motherboard. Replace the floppy drive.
0308h -
0309h
Transient DMA error. Rerun the test.
030Ah -
0310h
Rerun the test with a good floppy disk. Replace
the floppy drive.
0311h
Rerun the test with another floppy disk.
0321h -
0322h
Replace the floppy drive.
0340h
Replace the motherboard.
0380h -
03AAh
Make sure the floppy disk is fully inserted.
Check the connectors on the floppy drive and
motherboard. Replace the floppy drive.
03CCh
Run BIOS Setup and check the floppy drive
type. Rerun the test with another floppy disk.
Replace the floppy drive. Replace the
motherboard.
03EEh -
03FFh
Check the connectors on the floppy drive and
motherboard. Rerun the test with another
floppy disk. Replace the floppy drive. Replace
the motherboard.
Keyboard Tests
0400h -
0401h
Replace the motherboard.
0410h -
0414h
Check the keyboard flex cable connection.
Replace the keyboard. Replace the
motherboard.
0415h
Check icon PCA connections. Replace the icon
PCA. Replace the motherboard.
0416h -
0418h
Replace the keyboard. Replace the
motherboard.
Serial Port Tests
0601h
For the external loopback test, make sure the
loopback connector is installed and constructed
properly. For the external or internal loopback
test, replace the motherboard.
0602h
Replace the motherboard.
0603h
For the external loopback test, make sure the
loopback connector is installed and constructed
properly. For the external or internal loopback
test, replace the motherboard.
0604h -
0605h
Replace the motherboard.
0606h
For the external loopback test, make sure the
loopback connector is installed and constructed
properly. For the external or internal loopback
test, replace the motherboard.
0607h
Make sure the loopback connector is installed
and constructed properly. Replace the
motherboard.
0608h -
0611h
Replace the motherboard.
Parallel Port Tests
0701h
For the external loopback test, make sure the
loopback connector is installed and constructed
properly. For the external or internal loopback
test, replace the motherboard.
0702h
Replace the motherboard.