Include the appropriate number of physical drives in the arrays to create logical storage elements
of desired sizes.
Arrays
See
Figure 16
. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or more logical units (L1) called arrays. When this is
done, the read/write heads of all the constituent physical drives are active simultaneously, dramatically
reducing the overall time required for data transfer.
NOTE:
Depending on the storage server model, array configuration may not be possible or necessary.
P1
P3
P2
L1
gl0042
Figure 16 Configuring arrays from physical drives
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of
data stripes over all the hard drives in an array, as shown in
Figure 17
.
S1
S2
S3
S4
B1
B4
B7
B2
B5
B8
B11
B10
B12
B6
B3
B9
gl0043
Figure 17 RAID 0 (data striping) (S1-S4) of data blocks (B1-B12)
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the data blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array, the extra capacity is
wasted because it cannot be used by the array.
HP ProLiant Storage Server
53
Содержание ML110 - ProLiant G5 2TB Storage Server NAS
Страница 1: ...HP ProLiant Storage Server user guide Part number 440584 004 First edition February 2008 ...
Страница 50: ...Server components 50 ...
Страница 92: ...File server management 92 ...
Страница 110: ...Microsoft Services for Network File System MSNFS 110 ...
Страница 150: ...Troubleshooting servicing and maintenance 150 ...
Страница 152: ...System recovery 152 ...
Страница 158: ...BSMI notice Japanese notice Korean notice A B Class A equipment Class B equipment Regulatory compliance and safety 158 ...
Страница 172: ...Index 172 ...