Comments
Storage
Additional
Nodes
Node 1
Step
Power on the next node after the first
node is successfully configured.
Complete this process for all cluster
nodes.
Presented
On
On
Configuring
additional nodes
At this point all cluster nodes should be
on.
Presented
On
On
Post-installation
To configure the Cluster service on the storage server, an account must have administrative permissions
on each node.
Setting up networks
Verify that all network connections are correct, with private network adapters connected to other
private network adapters only, and public network adapters connected to the public network.
Configuring the private network adapter
The following procedures are best practices provided by Microsoft and should be configured on the
private network adapter.
•
On the
General
tab of the private network adapter, ensure that only TCP/IP is selected.
•
Ensure that the
Register this connection's address in DNS
is not selected in the DNS tab under
advanced settings for Internet Protocol (TCP/IP) Properties.
•
In all cases, set static IP addresses for the private network connector.
Configuring the public network adapter
While the public network adapter's IP address can be automatically obtained if a DHCP server is
available, this is not recommended for cluster nodes. HP strongly recommends setting static IP addresses
for all network adapters in the cluster, both private and public. If IP addresses are obtained though
DHCP, access to cluster nodes could become unavailable if the DHCP server goes down. If DHCP
must be used for the public network adapter, use long lease periods to assure that the dynamically
assigned lease address remains valid even if the DHCP service is temporarily lost. Keep in mind that
Cluster service recognizes only one network interface per subnet.
Renaming the local area connection icons
HP recommends changing the names of the network connections for clarity. The naming helps identify
a network and correctly assign its role. For example, “Cluster interconnect” for the private network
and “Public connection” for the public network.
Verifying connectivity and name resolution
To verify name resolution, ping each node from a client using the node's machine name instead of
its IP address.
HP ProLiant Storage Server
135
Содержание ML110 - ProLiant G5 2TB Storage Server NAS
Страница 1: ...HP ProLiant Storage Server user guide Part number 440584 004 First edition February 2008 ...
Страница 50: ...Server components 50 ...
Страница 92: ...File server management 92 ...
Страница 110: ...Microsoft Services for Network File System MSNFS 110 ...
Страница 150: ...Troubleshooting servicing and maintenance 150 ...
Страница 152: ...System recovery 152 ...
Страница 158: ...BSMI notice Japanese notice Korean notice A B Class A equipment Class B equipment Regulatory compliance and safety 158 ...