Chapter 2
Installing the Server
Cabling and Power Up
84
If the CE Tool is a laptop using Reflection 1, ensure communications settings are in place, using the following
procedure:
Step 1.
From the Reflection 1 Main screen, pull down the
Connection
menu and select
Connection
Setup
.
Step 2.
Select
Serial Port
.
Step 3.
Select
Com1
.
Step 4.
Check the settings and change, if required.
Go to
More Settings
to set Xon/Xoff. Click
OK
to close the More Settings window.
Step 5.
Click
OK
to close the Connection Setup window.
Step 6.
Pull down the
Setup
menu and select
Terminal
(under the
Emulation
tab).
Step 7.
Select the VT100 HP terminal type.
Step 8.
Click
Apply
.
This option is not highlighted if the terminal type you want is already selected.
Step 9.
Click
OK
.
Connecting the CE Tool to the Local RS232 Port on the MP
This connection enables direct communications with the MP.
Only one window can be created
on the CE
Tool to monitor the MP. When enabled, it provides direct access to the MP and any partition.
Use the following procedure to connect the CE Tool to the Local RS-232 Port on the MP:
1. Connect one end of a null modem cable (9-pin to 9-pin) (Part Number 5182-4794) to the cable connector
labeled CONSOLE.
2. Connect the other end of the RS-232 cable to the CE Tool.
Turning on Housekeeping Power and Logging in to the MP
After connecting the serial device, it is possible to log in to the Management Processor (MP). +3.3 DC
Housekeeping power (HKP) (also known as standby power) is active as soon as AC power is applied to the
server. As the MP uses housekeeping power, it is possible to log in to the MP even when the power switch is in
the OFF position. The power switch is a DC power switch that co48V DC.
Before powering up the server for the first time:
1. Verify that the AC voltage at the input source is within specifications for each server being installed.
2. If not already done so, power on the serial display device.
The preferred tool is the CE tool running Reflection 1.
To set up a communications link and log in to the MP:
1. Apply power to the server cabinet.
Содержание Integrity rx7640
Страница 4: ...Contents 4 ...
Страница 5: ...Contents 5 ...
Страница 6: ...Contents 6 ...
Страница 7: ...Contents 7 ...
Страница 8: ...Contents 8 ...
Страница 10: ...Tables 10 ...
Страница 13: ...Figures 13 ...
Страница 14: ...Figures 14 ...
Страница 40: ...Chapter 1 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview Detailed Server Description 40 ...
Страница 101: ...Index 101 ...