Chapter 2
Installing the Server
Installing Additional Cards and Storage
63
Installing Additional Cards and Storage
This section provides information on additional products ordered after installation and any dependencies for
these add-on products.
The following options may be installed in the server.
•
Additional hard disk drive storage
•
Removable media device storage
•
PCI and PCI-X I/O cards
Installing Additional Hard Disk Drives
The disk drives are located in the front of the chassis (Figure 2-17). The hard disk drives are hot-plug drives.
A list of replacement disk drives for the server is in Appendix A of the HP Service Guide. The list contains
both removable media disk drives and hard disk drives.
Figure 2-17
Disk Drive and DVD Drive Location
Use the following procedure to install the disk drives:
Step 1.
Be sure the front locking latch is open, then position the disk drive in the chassis.
Drive 1-1
Path: 1/0/0/3/0.6.0
Drive 1-2
Path: 1/0/1/1/0/4/1.6.0
Drive 0-2
Path: 0/0/1/1/0/4/1.5.0
Drive 0-1
Path: 0/0/0/3/0.6.0
DVD/DAT/
Slimline DVD Drive
Path: 1/0/0/3/1.2.0
Slimline DVD Drive
Path: 0/0/0/3/1.2.0