Boottest:
BOOTTEST Settings Default Variable
OS is not speedy boot aware.
Selftest Setting
--------- --------------
early_cpu Run this test
late_cpu Run this test
platform Run this test
chipset Run this test
io_hw Run this test
mem_init Run this test
mem_test Run this test
LAN Address Information:
LAN Address Path
----------------- ----------------------------------------
M 001 Mac(00237D447E94) PcieRoot(0x30304352)/Pci(0x1C,0x0)/Pci (0x0,0x0)/MAC(0023
7D447E94,0x0)
002 Mac0(0237D447E95) PcieRoot(0x30304352)/Pci(0x1C,0x0)/Pci (0x0,0x0)/MAC(0023
7D447E95,0x0)
003 Mac0(0237D448E5E) PcieRoot(0x30304352)/Pci(0x1C,0x2)/Pci (0x0,0x0)/MAC(0023
7D448E5E,0x0)
004 Mac0(0237D448E5F) PcieRoot(0x30304352)/Pci(0x1C,0x2)/Pci (0x0,0x1)/MAC(0023
7D448E5F,0x0)
FIRMWARE INFORMATION
System Firmware A Revision: 01.03
PAL_A: 4.29 SAL Spec: 3.20
PAL_B: 4.29 SAL_A: 2.00
UEFI Spec: 2.10 SAL_B: 3.01
UEFI Shell: 1.00 SMBIOS: 2.4
SYSTEM SECURITY CONFIGURATION
TPM: Not present
Shell>
Installation troubleshooting
Troubleshooting methodology
A server is tested before shipping. Failures encountered during installation can be due to damage
that occurred in transit. Reseating connectors can clear problems that result from rough handling.
If you are installing components or assemblies, compatibility problems or incorrect installations
can be the cause of the problems. If you are installing components or assemblies, verify that items
are correctly installed and that all connectors are fully engaged. If the unit does not power on,
verify the power source before proceeding.
If a problem is encountered during initial operation, remove any add-in or optional components
and retest the server before continuing. Verify basic server operation before installing additional
cards, and configuring software and hardware for the server requirements.
Troubleshooting is based on observation of server status indications and error messages, and by
checking system event logs. You can observe the LED indicators on the front and rear of the server.
Error messages are displayed on local and remote consoles. System history (console, event, and
history logs) is available through the iLO 3 MP, and is accessed through the console. Additional
information about troubleshooting is available on the CD provided with the server.
Troubleshooting using the server power button
The server power button on the front panel operates differently depending on how long the button
is pressed, and on what the system is doing when the button is pressed. You must be aware of its
uses to properly troubleshoot the system.
Installation troubleshooting