530
Step
Command
Remarks
group to use bidirectional
path switching.
switching-mode
bidirectional
on the tunnel bundle interface in 1:1
protection switching mode.
By default, the protection group in 1:1
protection switching mode uses
unidirectional path switching.
1+1 protection switching mode
supports only bidirectional path
switching.
Configuring command switching for the protection
group
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter the view of the
tunnel bundle interface in
the protection group.
interface tunnel-bundle
number
[
protection
{
onetoone
|
oneplusone
} ]
It is not required to specify the
protection switching mode when
you enter the view of an existing
tunnel bundle interface.
3.
Configure a switching
action.
protection switch
{
clear
|
force
|
lock
|
manual
}
By default, no switching action is
configured.
Configuring the PSC message sending interval
The two ends of a tunnel periodically send PSC messages to coordinate the protection state for
bidirectional path switching.
You can prevent PSC messages from occupying too much bandwidth and resources by modifying
the sending interval as needed.
To configure the PSC message sending interval:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter MPLS protection switching
view.
mpls protection
N/A
3.
Set the PSC message sending
interval.
psc message-interval
interval
By default, the sending interval is 5
seconds.
Displaying and maintaining MPLS protection
switching
Execute
display
commands in any view and
reset
commands in user view.
Task Command
Display tunnel bundle interface information.
display interface
[
tunnel-bundle
[
number
] ] [
brief