background image

4

Datacom specifications

Datacom interfaces:

 V.24,

V.11/X.21-leased, V.35.

Terminal emulation:

 DTE, DCE.

Timing modes:

 Synchronous

from 50 b/s to 2.048 Mb/s;
asynchronous from 50 b/s to
19.2 kb/s (except X.21-leased).

V.24 breakout
Isolation switches:

 TD, RD,

XTC, TC, RC, RTS, CTS, DTR,
DSR, DCD, situated between
drivers/receivers and interface
connector.

Four-state indicators:

 TD, RD,

XTC, TC, RC, RTS, CTS, DTR,
DSR, DCD and monitor.

Patch points and voltage
sources.

V.11/V.35 activity indicators
Data and clock:

 SD, RD, TT/

SCTE, ST/SCT, RT/SCR.

Control circuits:

 RS, CS,

TR/DTR, DM/DSR, RR/RLSD.

Synchronous mode
Clock sources:

 Internal

synthesizer, datacom interface.
(Selectable clock inversion.)

Interface clock rates:

 50 b/s to

2.048 Mb/s, 

±

 10 ppm.

Synthesizer rates:

 1.2, 2.4, 4.8,

9.6, 14.4, 19.2, 48, 56, 64, 384, 256,
512 kb/s, 1.024, 1.984 Mb/s,
variable (600 b/s to 2.048 Mb/s).
V.24 rate limited to 128 kb/s.

Datacom testing using the
HP 37732A telecom/datacom analyzer

Asynchronous mode
Rates:

 50, 75, 110, 134.5, 150, 200,

300, 600 b/s; 1.2, 1.8, 2.4, 4.8, 7.2,
9.6, 19.2 kb/s.

Character length:

 5, 6, 7 or

8 bits.

Parity:

 Odd, even, 0, 1 or none.

Stop bits:

 1, 1.5 or 2.

Data polarity:

 Normal or inverse.

Error add:

 Single, variable

10

2

 to 10

5

.

Test patterns
PRBS:

 63, 511, or 2047 bit, 2

15 

 1,

2

20 

 1.

Fixed:

 Permanent mark,

alternating mark/space inversion,
FOX message (asynchronous
mode only).

Word:

 User-defined word, 8 to

1024 bits in 8 bit intervals.

Test period:

 Manual, timed

interval (1 s to 100 days), bit
interval (10

n

 bits, n = 4 to 10).

HP 37732A telecom/datacom analyzer

Содержание HP 37722A

Страница 1: ...HP 37722A telecom analyzer HP 37732A telecom datacom analyzer Technical specifications ...

Страница 2: ... The HP 37732A telecom datacom analyzer provides testing at V 24 V 35 V 11 X 21 leased interfaces at rates up to 2 Mb s It also provides a full range of BER measurements control circuit timing analysis with transitions diagrams on the screen built in V 24 breakout box internal synthesizer event based storage in text and graphic form The HP 37732A analyzer reduces test time and speeds problem resol...

Страница 3: ...m 2 Mb s transmitter Output Ternary HDB3 or AMI Binary TTL data NRZ clock normal or inverted Error insertion Bit code Single variable 10 2 to 10 8 Frame error add FAS word NFAS bit CAS MFAS word CAS multiframe mode CRC MFAS word and CRC bits CRC4 multiframe mode Mode Burst continuous Alarm generation AIS 2 or 3 zeros in 512 AIS all ones remote alarm remote mutiframe alarm no signal Signaling bits ...

Страница 4: ...e clock inversion Interface clock rates 50 b s to 2 048 Mb s 10 ppm Synthesizer rates 1 2 2 4 4 8 9 6 14 4 19 2 48 56 64 384 256 512 kb s 1 024 1 984 Mb s variable 600 b s to 2 048 Mb s V 24 rate limited to 128 kb s Datacom testing using the HP 37732A telecom datacom analyzer Asynchronous mode Rates 50 75 110 134 5 150 200 300 600 b s 1 2 1 8 2 4 4 8 7 2 9 6 19 2 kb s Character length 5 6 7 or 8 b...

Страница 5: ... 2048 kb s code frame bit CRC4 REBE remote end block error E bits ITU T M 2100 analysis ES SES and availability for maintenance monitoring of transmit and receive directions Receive only for out of service testing includes PRBS defects and anomalies ITU T G 821 error analysis SES SES ES ES UAV and UAV telecom only percent availability datacom only US DM DM long term mean error ratio Also G 821 Ann...

Страница 6: ...0 n where n 2 to 6 Measurements Errors Bit frame Alarms Frame loss pattern loss remote alarm User channel interface Conforms to ITU T X 50 divisions 2 and 3 X 50 bis and X 58 as appropriate for 0 6 1 2 2 4 4 8 9 6 14 4 19 2 48 kb s Circuit numbering to ITU T X 53 Octet monitor Displays contents of any selected 8 bit envelope Monitors information bits and network bits Generate and measure X 50 and ...

Страница 7: ... to 20 dBm Connector BNC 75 ohm unbalanced ITU T M 2110 and M 2120 analysis Option 210 Measurement start at user specified time Summary print of current settings and counts ITU T M 2110 analysis for bringing paths into service 1 day and 7 day tests Wait pass fail test relative to user defined percentage path allocation ITU T M 2120 analysis for in service monitoring 15 minute and 24 hour contiguou...

Страница 8: ... 37732A analyzers under a quality system approved to the international standard ISO 9001 plus TickIT BSI Registration Certificate No FM 10987 For more information about Hewlett Packard test measurement products applications services and for a current sales office listing visit our web site http www hp com go tmdir You can also contact one of the following centers and ask for a test and measurement...

Отзывы: