215
1 1 hotspot 2 61 0 80 95 98
1 1 hotspot 3 57 0 80 95 98
1 1 hotspot 4 49 0 80 95 98
2 0 hotspot 1 34 0 75 85 90
2 0 hotspot 2 31 0 75 85 90
2 0 hotspot 3 44 0 65 80 85
2 0 hotspot 4 35 0 65 80 85
2 0 hotspot 5 53 0 65 80 85
2 1 hotspot 1 36 0 80 95 98
2 1 hotspot 2 61 0 80 95 98
2 1 hotspot 3 57 0 80 95 98
2 1 hotspot 4 49 0 80 95 98
Table 32 Command output
Field Description
Temperature Current
temperature.
Lower Low-temperature
threshold.
Warning High-temperature
warning
threshold.
Alarm
High-temperature alarming threshold.
Shutdown
High-temperature shutdown threshold. When the sensor temperature reaches the
limit, the system shuts down automatically.
display exception filepath
Use
display exception filepath
to display the directory for saving core files on an MPU.
Syntax
In standalone mode:
display exception filepath
[
slot
slot-number
[
cpu
cpu-number
] ]
In IRF mode:
display exception filepath
[
chassis
chassis-number
slot
slot-number
[
cpu
cpu-number
] ]
Views
Any view
Predefined user roles
network-admin
mdc-admin
Parameters
slot
slot-number
: Specifies an MPU by its slot number. If you do not specify this option, the
command displays the directory for saving core files on the active MPU. (In standalone mode.)
chassis
chassis-number
slot
slot-number
: Specifies an MPU on an IRF member device. The
chassis-number
argument represents the member ID of the IRF member device. The
slot-number
argument represents the slot number of the MPU. If you do not specify this option, the command
displays the directory for saving core files on the global active MPU. (In IRF mode.)
cpu
cpu-number
: Specifies a CPU by its number.