166
Software images on chassis 0 slot 10:
Current software images:
flash:/7900-CMW710-BOOT.bin
flash:/7900-CMW710-SYSTEM.bin
Main startup software images:
flash:/7900-CMW710-BOOT.bin
flash:/7900-CMW710-SYSTEM.bin
flash:/7900-CMW710-SSH.bin
Backup startup software images:
flash:/7900-CMW710-BOOT.bin
flash:/7900-CMW710-SYSTEM.bin
Table 21 Command output
Field Description
Software images on slot
slot-number
In standalone mode, this field displays the Comware images on
the MPU in a specific slot.
Software images on chassis
chassis-id
slot
slot-number
In IRF mode, this field displays the Comware images on a
specific MPU. The chassis ID represents the IRF member ID,
and the slot number represents the MPU's slot number.
Current software images
Comware images that have been loaded.
Main startup software images
Main Comware images for the next startup.
Backup startup software images
Backup Comware images for the next startup.
Related commands
boot-loader file
version auto-update enable
Use
version auto-update enable
to enable software synchronization from the active MPU to the
standby MPU at startup.
Use
undo version auto-update enable
to disable this feature.
Syntax
version auto-update enable
undo version auto-update enable
Default
If software inconsistency is detected at startup, the standby MPU loads the current software images
of the active MPU.
Views
System view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
This command is available only for the HPE 7910/HPE 7910 TAA switch in standalone mode.