80
Figure 50
LEDs on an LSX1SUP10A1 MPU
(1) Management Ethernet port LED (LINK)
(2) Management Ethernet port LED (ACT)
(3) Fan LED
(4) Power supply status LED
(5) Card status LEDs
(6) MPU active/standby status LED
Management Ethernet port LEDs
The MPU has one LINK LED and one ACT LED to indicate the link status and data forwarding status of the
management Ethernet port.
Table 40
Management Ethernet port LED description
LINK ACT
Description
On Flashing
A link is present, and the management Ethernet port is receiving or
sending data.
On
Off
A link is present.
Off
Off
No link is present.
Fan LEDs
The MPU provides two LEDs (OK and FAIL) to indicate the status of the fan tray.
Table 41
Fan LED description
OK FAIL Description
On
Off
All installed fan trays are operating correctly.
Off
On
A fan tray problem is present or no fan tray is in position.
Off
Off
The switch is not powered on.
Power supply status LED
The MPU provides two LEDs (OK and FAIL) to indicate the status of the power supplies.
Table 42
Power supply LED description
OK FAIL Description
On
Off
All installed power supplies are operating correctly.
Off
On
At least one power supply is faulty.
Off
Off
The switch is not powered on.