Preparation for Use
Chapter 1 of the HP E1418A User’s Manual contains complete instructions
for installing the module in a mainframe and installing a terminal module.
Refer to the mainframe user’s manual, command module user’s manual, and
the Installing Device Drivers installation note to prepare the mainframe.
Prepare the Module
Verify or set the module’s logical address. Refer to the HP E1418A User’s
Manual for instructions. In this manual the factory default logical address
of 72 is used.
To prepare the module for the adjustment procedures in Chapter 5, set or
verify the position of the CAL Secure Enable Jumper before installing the
module in the mainframe. (The jumper is factory set to CAL.) Figure 5-2 on
page 62 shows this jumper.
Prepare the
Terminal Module
The procedures in this manual show the screw-type terminal module. To
prepare this terminal module, you will need to set the jumpers and make
connections. If you are using other types of terminal modules, consult the
HP E1418A User’s Manual for proper connections.
Terminal Module
Jumpers
The screw-type terminal module contains jumpers that control how the
HP E1418A operates. To prepare the module for the Verification Tests in
Chapter 4 and Adjustments in Chapter 5, the terminal module jumpers must
be set to allow the module to be programmed from the backplane. The
HP E1418A will operate without any jumpers installed. Figure 2-1 shows
the jumper locations and example settings.
There are two jumpers for each channel; a P/J jumper and a V/I jumper.
The two jumpers work together.
The P/J jumper sets the channel output mode to be either Program
Selectable or Jumper Selectable. When the jumper is in the program
selectable position, the channel output mode can be set via programming
commands. The program selectable position is recommended for the
Verification Tests and Adjustment procedures in this manual. In the jumper
selectable position, the channel output mode is set via the V/I jumper.
The V/I jumper sets the channel output mode to either voltage or current
when the P/J jumper is set to the Jumper Selectable position. When the P/J
jumper is set to Program Selectable, this jumper has no effect.
16 Installation
Chapter 2
Содержание E1418A
Страница 4: ...Notes 4 HP E1418A 8 16 Channel D A Converter Service Manual Contents ...
Страница 8: ...Notes 8 HP E1418A D A Converter Module Service Manual ...
Страница 58: ...Notes 58 Verification Tests Chapter 4 ...
Страница 66: ...Figure 5 5 Internal Resistor Adjustment Connections 66 Adjustments Chapter 5 ...
Страница 81: ...Figure 6 1 8 Channel Disassembly Chapter 6 Service 81 ...
Страница 82: ...Figure 6 2 16 Channel Disassembly 82 Service Chapter 6 ...
Страница 83: ...Figure 6 3 Plug on Channel Locations Figure 6 4 Installing Plug on Modules Chapter 6 Service 83 ...
Страница 84: ...Notes 84 Service Chapter 6 ...
Страница 90: ...Figure 7 1 HP E1418A Replaceable Parts 90 Replaceable Parts Chapter 7 ...
Страница 91: ...Figure 7 2 Common Terminal Module Replaceable Parts Chapter 7 Replaceable Parts 91 ...
Страница 94: ...Notes 94 Manual Changes Chapter 8 ...